n Disable buzzer
If the Keypad buzzer is Enabled, it will signal the Entry
and Exit Times, and Violation on Chime zones. This
command will allow you to Disable these audible si-
gnals.
When you select this command the display will show
the following message:
Disable
buzzer
Buzzer OFF
Press OFF to Disable the buzzer.
Press
1 to Enable the buzzer with low volume.
Press
2 to Enable the buzzer with high volume.
Press the ENTER key to step back to the User menu.
+
This command will not Disable the audible feed
back signal sounded by the keys .
n Test Siren
This command will allow you to Test the proper working
order of the Alarm signalling devices. If you select this
command the Control panel will activate the devices,
and the display will show the following message:

Test Siren

done!
n Test Keypad
This command will allow you to Test the proper working
order of the display, LEDs and Keypad. If you select this
command the display will show the following message:
USER MENU

Test keypad

1. Press ENTER:
ABCDEFGHIJKLMNOP
ABCDEFGHIJKLMNOP
If the display is working properly, it will show letters A to
P on both lines.
If the I, a, G and M indicator LEDs are working pro-
perly, they will blink for several seconds.
If the buzzer is working properly, it will sound three ti-
mes.
n Continuous recording
This command will allow you to record sounds picked
up by the system microphones, during and after Alarm
and generic events.
To playback sound recording:
1. Use A or B to scroll for the Cont. rec. ack option.
+
This command cannot be selected until one of the
Events, programmed by the Installer, occurs.
KYO320
OPERATING YOUR SYSTEM FROM A KEYPAD
Continuous rec.
Cont.rec.ack
2. Press ENTER to start the sound recording playback
Continuous rec.
RemainingSec.030
The second line of the display will show the elapsing ti-
meout. When the remaining seconds go to zero the
Continuous Recording elapses.
To reset this command:
1. Use A or B to scroll for Cont.rec. reset:
Continuous rec.
Cont.rec. reset
2. Press ENTER to reset the Continuous Recording fa-
cility, and step back to the User menu.
n Enable/Disable Timers
This Control panel manages up to 64 Timers for control
of the ON/OFF Times of electrical appliances (Heating
systems, Garden sprinklers, Courtesy lights, etc.), and
Enabled Times of the system objects (Outputs, Codes,
Keys, Cards, etc.). Ask your Installer for details. The
En/Dis Timer option will allow you to Enable/Disable
the Timers, as follows:
1. Use A or B to scroll for the Timer concerned.
Timer
001
Timer ON
2. Press ON to Enable, or OFF to Disable the Timer.
3. Press ENTER to confirm and go back to the User
menu.
n Enable/Disable Key
The En/Dis Key option will allow you to Enable/Disable
the Keys, as follows:
1. Use A or B to scroll for the Key concerned, or enter
its ID Number.
Key
001
Key
ON
2. Press ON to Enable, or OFF to Disable the Key.
3. Press ENTER to confirm and go back to the User
menu.
+
NOTE: A Key can be Enabled/Disabled ONLY by
Codes which operate the Partitions it is assigned to.