The parameters description and programming is shown in
the following KeyFobs page (Fig.51).
This field shows the keyFob identification number
N.
which will be used in different parts of the application.
Description
This editable field (16 characters) is for
the KeyFobs (e.g. the name of the Key User). This De-
scription will identify the KeyFob in all the operations it is
involved in.
1, 2, 3...32
These numbers correspond to the Parti-
tions. The KeyFob can be programmed to operate in 3
different modes on the system Partitions.
On/Off Button This row will allow you to Enable/Dis-
able the KeyFobs on the Partition (Check= KeyFob en-
abled on the relative Partition).
A mode (Amber) This row will allow you to enable the
status the Partition will assume when the KeyFob
makes an A Mode Arming request. The box will indi-
cate the selected mode (see the Mode section: A=
Away, S= Stay, I= Stay o Delay, D= Disarm, N= No
change.
B mode (Green) This row will allow you to enable the
status the Partition will assume when the KeyFob
makes an B Mode Arming request. The box will indi-
cate the selected mode (see the Mode section: A=
Away, S= Stay, I= Stay o Delay, D= Disarm, N= No
change.
Figure 51 Wiring diagram for the serial link between the Control panel and PC
84
1
6
2
7
3
8
4
9
5
a)
DB9 female
connector
5
9
4
8
3
7
2
6
1
b)
DB9 female
connector
Serial Number This editable field is for the ESN
6-digit
(Electronic Serial Number) of the KeyFob
(printed on back). The ESN may include hexadecimal
digits (A, B, C, D, E and F), in order to lower the risk of
duplicate ESNs.
To replace KeyFob: select the required Wireless key,
then enter the ESN of the new Wireless Key in the Se-
rial Number field.
To enrol a KeyFob: select an empty key placement
(ESN = 0) then enter the Wireless Key ESN in the Serial
Number field.
To unenrol a KeyFob: select the required Wireless Key
then enter 000000 in the Serial Number field.
+
If you press the SHIFT button and click on A or B
Arming type the arming mode will change on all the
partitions.
+
If you click on Partition number the arming mode
will change on all the KeyFobs.

Clock

Proper functioning of the Scheduler/Timers depends on
the Clock setting (Clock page), therefore, the Control
panel clock must be set with extreme precision.
Actual Date Set the current date.
Actual Time Set the current time.
Date format Select the Keypad date format:
7-wire cable
shield
7-wire cable
shield
1
6
2
7
3
8
4
9
5
DB9 female
connector
13
25
12
24
11
23
10
22
9
21
8
20
7
19
6
18
5
17
4
16
3
15
2
14
1
DB25 female
connector
KYO 320