The list on the left side of the page shows the Wireless
Zones of the system. The following information is
shown for each Wireless Zone.
+
If the Wireless Device Receiver option is Disabled
(refer to the Accessories page), the left side of the
Wireless page will be empty.
No. This field shows the Wireless Zone which will be
used in some parts of the application instead of the
Wireless Zone.
Position This field shows the Description of the hard-
ware device the Wireless Zone is assigned to.
Description This editable field (16 characters) is for the
Wireless Zone (e.g. the detector placement or the name
of the Key User). This Description will identify the Wire-
less Detector in all the operations it is involved in.
The right side of the page will allow you to program the
parameters of the Wireless Device (to be selected on
the left), as follows.
+
The right side of the page shows the various pa-
rameters for the Wireless Zones.
Serial Number This editable field is for the ESN (Elec-
tronic Serial Number) of the Wireless detector which is
assigned to the selected Wireless Zone.
+
You cannot program the device parameters until
you have entered its ESN.
The ESN will allow the Control panel to identify the wire-
less device on the system.
The ESN may comprise hexadecimal digits (A, B, C, D,
E and F), in order to lower the risk of duplicate ESNs.
+
Some Wireless Devices have 5-digit and 6-digit
ESNs (printed on back), use ONLY 6-digit ESNs
with this Control panel.
Supervised If this option is Enabled, the sys-
tem will be able to signal the loss of the Wire-
less detector. The Receiver will trigger the
Lost wireless zone event as soon as the
programmed Supervisory time expires (refer
to the Time supervision zones under "Ac-
cessories" in the "Configuration" section).
The placement of Wireless detector will not
be indicated, however, the respective infor-
mation will be recorded in the log.
Type Refer to "Type" under "BPI Zones".
Voice Messages Refer
sages" under "Wired Zones".
Attributes Refer to "Attributes" under "Hard-
wired Zones".
KYO 320
to
"Voice
mes-
Figure 29 Outputs page
PROGRAMMING FROM THE PC
Cycles Refer to "Cycles" under "Hardwired Zones".
Partitions Refer to "Partitions" under "Hardwired Zones".
Full Arming Alarm Refer to "Full Arming Alarm" under
"Hardwired Zones".
Inactivity Refer to "Inactivity" under "Hardwired Zones".
+
The Inactivity Time of Wireless Zones must not be
less that 5 minutes.
n Replacing Wireless Devices
To replace a Wireless detector (assigned to a Wireless
Zone): select the required Wireless Zone, then enter
the ESN of the new Wireless detector in the Serial
Number field.
n Enrolling Wireless Devices
To enrol a Wireless detector: select an empty Wireless
Zone, then enter the Wireless detector ESN in the Se-
rial Number field.
n Unenrolling Wireless Devices
To unenrol a Wireless detector (assigned to a Wireless
Zone): select the required Wireless Zone then enter
000000 in the Serial Number field.

Outputs

Control panel Outputs no. 1, no. 2 and no. 3 are 3 A dou-
ble switching relays. The terminals for these Outputs are:
Ø Output no. 1 = +N1, +A1, C1-NC1-NA1
Ø Output no. 2 = +N2, +A2, C2-NC2-NA2
Ø Output no. 3 = +N3, +A3, C3-NC3-NA3
The Control panel Outputs no. 4, no. 5 and no.6 are 1 A
Open-Collectors. The terminals for these Outputs are:
OC1, OC2 and OC3.