3. Enter the Overtime length (in minutes), then press
ENTER to go to the next parameter. Valid entries: 0
through 60 minutes.
Max overtime n.
(Max 009)
003
4. Enter the maximum number of overtime requests allo-
wed, then press ENTER to go back to the PROGRAMMING
menu. Valid entries: 0 through 9 requests.
+
NOTE: The Overtime length value multiplied by
the Max. overtime requests value MUST NOT ex-
ceed 180 minutes.
Option block 1
No_us.res.tamp.
Test_zone_dis.
Delay_bat.Test
No_ist.res.al.
No_key>leds_off
Bypass_z.tamp.
Test_bat.to_arm
Cont.recording
Option block 2
Block_inst.code
No_arm_z.open
Legal
Time____
DTMF Voice menu
Logger on RS232
ZoneAlarmFlash
Chime in memory
Option block 3
Code Hierarchy
Tamp.OnExpInLoss
Tamp.OnKeyp.Loss
Realtime Chime
38
Corresponding option
Disable tamper memory reset
with User code
Maintain Zone Test Attribute
Enable dynamic battery test
timeout after mains restoral
Disable alarm memory reset
with Installer code
LEDs OFF on Readers
Bypass tamper on zone
Disable arming on battery
trouble
Enable continuous recording
Corresponding option
Lock Installer code
Disable arming on partition
alarm
Enable automatic changeover
Standard time/Summer time
Voice guide for commands
made over the phone
NOTE: This option is available
via Keypad only.
Shows open zones on the
keypad display
Shows Chime zones on the
Keypad display (memory)
Corresponding option
The user can choose whether to
enable the Installer code or not
Generates a Tamper
event if the Expander In
is not detected
Generates a Tamper
event if the Keypad
is not detected
Shows Chime zones on the
Keypad display (real time)
Disab.False Key
NoArmReceivLost
NoArm ZoneTroub
Table 9 Keypad options and their corresponding Com-
puter Software options

Default PIN

The Installer Code default PINs can be found in Table 10:
Ø the no. column shows the ID Number of the respecti-
ve Installer Code;
Ø the Description column is for the label of the respec-
tive Installer Code;
Ø the PIN column shows the PIN of the respective
Installer Code, if it is "Active" and "Unhidden" (refer to
the "Installer PIN" under "KEYPAD OPERATIONS").
n.
Description
196
197
198
199
200
Table 10) KYO320 installer code Default PIN.
Disable false key event
Disable arming on wireless
receiver lost
Disable arming on wireless zone
fault
KYO320
PIN
0196
0197
0198
0199
0200