Code> On; Code> Off - Bentel Security KYO 320 Installation Manual

Expandable multifunction control panel
Hide thumbs Also See for KYO 320:
Table of Contents

Advertisement

commands — except 'View Trouble' — require entry a
valid User Code PIN.
Keypad set normally
Enter
<Code> ON
<Code> OFF
<Code> A
<Code> B
<Code> C
<Code> D
<Code> ENTER
ONLY ENTER
List "By-passed zones"/"By-
ONLY ESC
Keypad set as EN50131
Key sequence (from
standby status)
<Code> ON
<Code> OFF
<Code> A
<Code> B
<Code> C
<Code> D
Message
The Control panel battery or at least one Power Station is not functioning properly
Tr oub. _pow. s y s t .
The Control panel battery or at least one Power Station battery is low
Low_bat t er y
AC_M ai ns _f ai l ur e The Mains pow er to the Control panel or to at least one Pow er station has failed
At least one Pow er Station has disconnected its Battery
Bat t . _di s c . pw. s .
At least one Pow er Station has Battery-charger trouble
Faul t _c hr g. pw. s .
At least one Pow er Station has disconnected its Battery-charger
Swt c h. di s c . pw. s .
At least one Pow er Station has one Output in short-circuit
Out _s hor t __pw. s .
Line down
Tel . _l i ne_t r oub.
Shortcuts/blown fuse on terminals +N1 and +A1 (1.85A-250V)
Fus e_B1
Shortcuts/blown fuse on terminals +N2 and +A2 (1.85A-250V) KYO320 only
Fus e_B2
Shortcuts/blown fuse on terminals +N3 and +A3 (1.85A-250V) KYO320 only
Fus e_B3
Shortcuts/blown fuse on terminals +B4 (1.85A-250V) KYO320 only
Fus e_B4
Shortcuts/blown fuse on terminals +B5 (1.85A-250V) KYO320 only
Fus e_B5
Shortcuts/blown fuse on the power line +F (1.85A-250V)
Fus e_+F
Shortcuts/blown fuse on BPI line1 (1.85A-250V)
Fus e_BPI _1
Shortcuts/blown fuse on BPI line2 (1.85A-250V)
Fus e_BPI _2
Shortcuts/blown fuse on the Key Bus (500 mA-250V)
Fus e_KEYBUS
STOP ALARM jumper is connected
St op_al . j um p. i n
Low Battery on one or more Wireless devices
Low_bat t er y _W LS
The RAM battery must be replaced
W ar n. l i t hi um bat t
Service is due — Call your Installer
Cal l I ns t al l er
Central Station intervention is due — Call your Central Station
Cal l Cent r . St at .
The Control panel Clock has been turned forward/back
Day l i ght Sav i ng
Connection problems with a Wireless device (Missing or Trouble present)
W LS Dev i c e l os t
The Control panel Clock has stopped
Cl oc k St opped
Connection problems with the Vox Board (Missing or Trouble)
Vox _boar d_l os t
Programming session via PC (on-site or via Modem) started during Disarmed status
St ar t _pr ogr am .
The zone"Inactivity Time" has expired
I nac t i v i t y
A PIN (DUPLICATED at random) has been DISCLOSED to another User
Di s c l os ed PI N
KYO320
COMMAND
Arm
Disarm
A Mode Arm
B Mode Arm
C Mode Arm
D Mode Arm
Access User Menu
"View trouble" mode
passed zone"
COMMAND
Arm
Disarm
A Mode Arm
B Mode Arm
C Mode Arm
D Mode Arm
TABLE 5 - "VIEW TROUBLE" MODE
OPERATING YOUR SYSTEM FROM A KEYPAD
View Area status if there are no
malfunctions, otherwise View
<Code> ENTER
From the View area status or
malfunctions screen, press
ENTER again to access the
+
'View Trouble' mode is available on LCD Keypads
at all times, and can be accessed without entering
a Code.
+
Commands will affect only the Partitions common
to both the User code and Keypad concerned
(common Partitions).
Invalid commands will be signalled by a buzz and the
following message:
17:05 26/08/2005
Invalid code!
invalid commands may be due to the User code or the
Keypad (e.g. the User code is Disabled on the Keypad
Partitions).
+
If you do not press a key within 30 seconds, the
keypad will revert automatically to standby status.
Description
malfunctions.
User menu.
7

Advertisement

Table of Contents
loading

Table of Contents