part.alarm (refer to "Stop Partition Alarms"), Print logger
(NOT available!). Press ON or OFF, respectively, to ena-
ble or disable the function concerned ("û" means enabled,
and "-" means disabled). Press ENTER to go to step 3.
Option section 5
Arming type
A x
9. Using A or B, select the functions from Option sec-
tion 5: Arming type A (refer to "Arming A with user
code"), Arming type B (refer to "Arming B with user
code"), Arming type C (refer to "Arming C with user
code"), Arming type D (refer to "Arming D with user
code"), Away arming (refer to "Away arming with user
code"), Disarming (refer to "Disarming with user
code"). Press ON or OFF, respectively, to enable or di-
sable the function concerned ("û" means enabled, and
"-" means disabled). Press ENTER to go to step 3.
n Installer Code Types
Option block
Event logger
5a. Using A or B, select the functions from Option sec-
tion 1: Event logger (refer to "View logger"), Zone sta-
tus (refer to "Zone Status"), Zone test (refer to "Zone
Test"), Outputs test (refer to "Output Test"), Clear call
queue (refer to "Clear Call Queue"), Voice functions
(refer to "Voice Functions"), Installer PIN (refer to
"Change Installer PIN"), User codes (refer to "User Co-
des"). Press ON or OFF, respectively, to enable or disa-
ble the function concerned ("û" means enabled, and "-"
means disabled). Press ENTER to go to the next Option
section.
Option block
Digital Keys
6a.Using A or B, select the functions from Option section 2:
Digital keys (refer to "Digital Keys"), Program Panel (refer
to "Panel programming"), Enrol wireless (refer to "Enrol
Wireless"), Update strings (refer to "Keypad Broadcast"),
Change time/date (refer to "Change date/time"). Press
ON or OFF, respectively, to enable or disable the function
concerned ("û" means enabled, and "-" means disabled).
Press ENTER to go back to step 3.
N
0000 + n
Alarm on zone no.
0280 + n
Alarm on zone no. – Wireless
0344 + n
Tamper on zone no.
0624 + n
Tamper on zone no. – Wireless
Tabella 1 Zones events for KYO320
N
0688 + n
Fire alarm on partition no.
0720 + n
24h alarm on partition no.
0752 + n
Burglar alarm on partition no.
KYO320
1
x
2
x
EVENT
EVENT
PROGRAM PANEL
0784 + n
Generic alarm on partition no.
0816 + n
Tamper alarm on partition no.
0848 + n
Generic+Tamper alarm on partition n.
0880 + n
Away alarm on partition no.
0912 + n
Stay alarm on partition no.
Tabella 2 Partition events for KYO320
N.
0945
Fire alarm on panel
0946
24h alarm on panel
0947
Burglar alarm on panel
0948
Generic alarm on panel
0949
Tamper alarm on panel
0950
Generic+Tamper alarm on panel
0951
Tamper on Main unit
0952
Stop-alarms jumper
0953
Balanced tamper
0953 + n
Tamper on supervised output no.
0957
Tamper BPI readers
0958
Tamper BPI input expanders
0959
Tamper keypads
0960
Tamper LED Keypad
0961
Tamper output expanders
0962
Tamper power stations
0963
Tamper wireless device
Tabella 3 KYO 320 Panel events
N.
0964
Warning readers
0965
Warning BPI input expander
0966
0967
Warning LED keypad
0968
Warning output expanders
0969
Warning power stations
0970
Warning wireless device
0971
0972
Warning fuse +F
0973
Warning fuse +B1
0974
Warning fuse +B2
0975
Warning fuse +B3
0976
Warning fuse +B4
0977
Warning fuse +B5
0978
Warning fuse BPI1
0979
Warning fuse BPI2
0980
Warning fuse KEYBUS
0981
Warning mains failure
0982
Warning low battery
0983
Warning power trouble
EVENTI
EVENTI
Warning keypad
False key