played each time the Control Panel answers a call after
the programmed number of Rings.
+
The Answering Machine function can
abled/Disabled by the User (refer to "Enable/Dis-
able
Answering
MANUAL).
If the Teleservice function is also Enabled, the Control
Panel will emit a beep, wait approximately 6 seconds
for the Modem to respond (if connected) and, if no re-
sponse is detected, will play the Message. If the An-
swering Machine Message has not been recorded the
Control panel will emit a beep.
The layout of the Answering Machine window is as fol-
lows.
Answer Message This field will allow you to select the
Answering Machine Voice Message (refer to "Voice
Messages").
Message Repetitions This field will allow you to pro-
gram the number of times the message must be played.
Valid entries: 0 through 255;
Default setting: 3.
Replay Pause This field will allow you to program a
pause between Answer Message announcements.
Valid entries: 1 through 254, in 1-second steps;
Default setting: 5 seconds.
PIN Timeout This field will allow you to program the
time the User will have to enter the User Code (with re-
mote Telephone Access) on the telephone keypad.
Valid entries: 1 through 254 seconds, in 1-second steps
Default setting: 30 seconds.
+
Only Codes no. 132 to 195 can access the Control
Panel via telephone (refer to the "Codes" paragraph).
DTMF Tone Timeout This field will allow you to pro-
gram the time (in seconds) the User will have to enter
the Command after Code acceptance. The
User must start entering the command before
the Timeout ends, otherwise, the Control
Panel will end the call. Valid entries: 1 through
254 seconds, in 1 second steps. Default set-
ting: 30 seconds.

Dialler

The Dialler page will allow you to define up to
50 Actions. Each Action can be associated
with one or more Events in the Events-Ac-
tions page. The Actions will signal via Tele-
phone the start and/or end of their associated
Events. Each Dialler Action can send a Voice
Message to a maximum of 32 Telephone
numbers.
Message Queue The Dialler will not end the
call until all the messages destined for the
KYO 320
be En-
Machine"
in
the
USER'S
Figure 34 Dialler page
PROGRAMMING FROM THE PC
connected telephone number have been sent. This fea-
ture reduces call time and costs.
+
Events will not be queued when the Call success-
ful number option is Enabled (refer to "Options"
under "Dialler").
The layout of the Dialler page is as follows.
+
The Dialler parameters apply to all the numbers in
the Dialler book.
n Dialler book
The Dialler book will allow you to assign up to 32 Tele-
phone numbers from the General book (refer to "Tele-
phone") to the Dialler function.
No. This is the Identifier number (1 through 32) which
represents the Telephone number in the Actions win-
dow.
This
Identifier
CORRESPOND to the Telephone Number ID number
in the General Phonebook.
Telephone Number This field will allow you to select
the Telephone Number the Dialler must call.
1. Click on the field you wish to program.
2. Click again on the same field: the program will dis-
play the Telephone Numbers in the General
Phonebook.
3. Select the required Telephone Number.
+
The ID numbers can be entered in any order. How-
ever, the sequence defined in the Dialler
phonebook will determine the call priority.
n Send Message after ...
This section will allow you to program when the Voice
Message announcement.
number
DOES
NOT
49

Advertisement

Table of Contents
loading