or similar. The installation instructions can be found in
the MINI-BOX package.
+
The Microphone and Loudspeaker should be hou-
sed in separate boxes.
"Voice Modules" should be mounted in places
which allow easy access.
DO NOT mount VOX-REM Microphone-Speaker
boards until you have tested the placements for
squealing.
Connect the "Voice Modules" in parallel to the Voice bo-
ard, as shown in Figure 3. The number of "Voice Modu-
les", and the connection lengths can affect sound
quality, therefore:
Ø DO NOT connect more than 4 "Voice Modules" to the
Voice board.
Ø DO NOT use more than 50 metres of cable between
each "Voice Modules" and the Voice board.
+
In order to improve message quality, use the Voice
Board Microphone, and temporarily disconnect the
other "Voice Modules".
All "Voice Modules" will be interconnected during Tele-
assistance mode thus allowing users to communicate
with one another.
n Manual selection
Installation of several "Voice Modules" will allow the user
to listen-in on the various parts of the premises at the
same time, however, sound tracing will not be possible.
For sound tracing—complete the connections, as
shown in Figure 4. The wiring diagram shows the Voice
board and 4 "Voice Modules", and also:
Ø an M-IN/OUT Expanders programmed as Expander
with 6 Outputs.
Ø an M-IN/OUT Expanders programmed as Expander
with 6 Zones.
Ø two Omnia/4R Relay modules
The Control panel must be programmed as follows:
Voice Board
SPK-
SPK+
MIC
+12
SP-
SP+
MIC
VOX-REM
Figure 3 Connecting 4 VOX-REM Microphone Board
40
Ø All the Outputs of the M-IN/OUT Expander, program-
Ø All the Zones of the M-IN/OUT Expander, program-
Enable Remote Listen-in via Telephone
1. Press 3 (to access Outputs Management).
2. Press 1 (to select ON), then enter the number (3 di-
3. Press 1 (to start the Remote Listen-in session).
For example, if the M-IN/OUT Expander, programmed
as Expander with 6 Outputs (see "M-IN/OUT Program-
mable Input/Output Expander" in the Installation Ma-
nual, Vol.1), is assigned address no.01, its hardware
outputs T1, T2, T3 and T4 correspond respectively to
software outputs nos. 7, 8, 9 and 10. Therefore, to acti-
vate the first "Voice Module" (connected to hardware
Output T1 — software Output no. 7) enter: 310071 (3 to
access Outputs Management; 1 to select O; 007 to se-
lect Output no. 7; and 1 to start the Listen-in session).
4. To Listen-in on other parts of the premises during
n Auto-select mode
The Auto-select mode will allow the Control panel to se-
lect the nearest "Voice Module" to the zone in alarm. Fi-
gure 4 shows the necessary wiring. The Outputs and
Event-Actions must be programmed, as follows.
SP-
SP+
MIC
VOX-REM
med as Expander with 6 Outputs, as such must be
Reserved Outputs (manual), Bistable, Normally
Open;
med as Expander with 6 Zones, must be Instant, Re-
petitive, Normally Open (DO NOT assign these to
Partitions). The zones must be associated with a
Standby Voice message that identifies the location
of the zones (e.g. Kitchen, Sitting room, etc.).
gits) of the required "Voice Module" Output.
the same call: press # (to stop the active "Voice Mo-
dule".); 3 (to access Outputs Management); 0 (to
select OFF); enter the Identifier number of the acti-
ve "Voice Module" Output (3 digits — 007 in the
example), then repeat steps 1 through 3.
SP-
SP+
MIC
VOX-REM
SP-
SP+
MIC
VOX-REM