And-Zone Groups - Bentel Security KYO 320 Installation Manual

Expandable multifunction control panel
Hide thumbs Also See for KYO 320:
Table of Contents

Advertisement

spectively, to enable or disable the respective attribute.
The display will show the attribute status: "û" means
Active, "-" NOT active.
7b. Press ENTER.
Cycles
Repetitive
This programming field will allow you to program the
number of times the zone will generate the Alarm on
zone - Via Radio event.
Valid entries: 1 through 254 or Repetitive.
8b. Enter the required number of cycles, or enter all ze-
ros to set Repetitive, then press ENTER.
All.message ---
None
This programming section will allow you to assign two
voice messages (from the 62 available) to the wireless
zone being programmed. You can assign one message
to Standby status and another to Alarm status.
If you select "None" in the Alarm Message field, Alarm
status will be signalled by two beeps, when the system
is accessed over the phone.
If you select "None" in the Standby Message field,
Standby status will be signalled by one beep, when the
system is accessed over the phone.
9b.Using A or B, select the message number or
"None", then press ENTER.
10b. For the Standby message, repeat step 9b, then
press ENTER.
Stdby mes.n. ---
None
11b. Assign the Zone to the respective Partitions (refer
to "Enabling Partitions and A, B, C and D Mode" under
"Using the Keypad"), then press ENTER.
Partition
x
12b.Using A or B, select the Enable autoarm option
(refer "Auto-arm on delay") or Full arming Al. (refer
to "Full Arming Alarm"). Using ON or OFF, respectively,
enable or disable the option concerned.
Press ENTER to confirm and go to the next step.
Options
Enable autoarm -
13b.If the Enable Autoarm option is OFF, go to step
14b. If the Enable Autoarm option is ON, enter the re-
quired timeout (refer to "Inactivity Time"), then press E
to confirm and continue.
24
1-8
Timeout
Disabled
14b.Enter the Inactivity Time (refer to "Inactivity").
Using 0, select Disabled to disable Inactivity supervi-
sion.
Inactivity time
Disabled
Press ENTER to confirm and continue.

AND-zone Groups

This programming section will allow you to create up to
32 AND-Zone groups. Each AND-Zone group can in-
clude up to 8 Zones. If a Zone is included in an
AND-Zone group it will generate Alarms ONLY when
ALL the Zones in the Group are violated within a set
time
(refer
to
"Zones
"PROGRAMMING").
From the PROGRAMMING menu:
PROGRAMMING
Configuration
1. Using A or B, select the AND-Zone Groups option.
PROGRAMMING
AND-Zone Groups
2. Press ENTER.
AND-Zone Groups
Number
01
3. The display will show the ID Number of the first
AND-Zone Group. If you require a different AND-Zone
Group, use A or B, or enter the respective ID Number,
then press ENTER. To exit this programming section,
press ESC.
AND-Zone
1___
Zone
001
4. Using A or B, select the first Zone to be included in
the AND-Zone Group, or enter the respective 3 digit
Zone ID Number (for example, enter 003 for Zone 3).
Press ENTER to go to the successive programming
field.
+
NOTE: To delete an AND-Zone from a Group, en-
ter 000 in the respective programming field.
AND-Zone Window
hh.mm.ss00.00.00
5. Once the AND-Zone Group has been set up, pro-
gram the AND-Zone Window (in hours, minutes and
seconds ). The system will not generate Alarms unless
in
AND
Mode"
under
KYO320