To unenrol an Output Expander
guration), press OFF.
5. Press ESC to go back to the Configuration menu.
n Power Station
This Control panel is unable to support Power stations.
The following instructions are for upgraded models only.
From the Configuration menu, using A or B, select the
Power stations option:
Configuration
Power stations
1. Press ENTER
Power stat.

PowerStation 001

2.Using A or B, select the Power Supply Station to be
programmed then press ENTER.
Description
PowerStation 001
3. Enter the Power Supply Station label (refer to "Editing
a text" under "Using the Keypad"), then press ENTER.
PowerStation 001
Not present
4. Press ON to enrol the Power Station (Present), then
press ENTER to continue. To unenrol the Power Sta-
tion (delete from the Configuration), press OFF.
5. Enter the Mains Fault Timeout, that is, the amount
of time (in seconds) that must expire before the system
generates the Mains Failure on Power Station event
(refer to the INSTALLATION MANUAL), then press
ENTER.
Main Fault Delay
Sec.
0180
6. Enter the Low battery delay, that is, the amount of
time (in seconds) that must expire (after a reading be-
low 11.4 V) before the system generates the Low Bat-
tery
on
Power
Station
INSTALLATION MANUAL).
Batt.Low Delay
Sec.
0180
7. Press ENTER to continue the Power Station enrolling
phase, or ESC to go back to the Configuration menu.
n Wireless Module
This Control panel can support a Wireless Receiver.
From the Configuration menu, using A or B, select the
Wireless module option.
20
2
(delete from the Confi-
001
event
(refer
to
Configuration
Vector-RX module
1. Press ENTER:
Vector-RX module
Not present
2. Press ON to enrol the Receiver (Present), then press
ENTER to continue. To unenrol the Receiver (delete
from the Configuration), press OFF.
Supervision time
hh.mm
3. Enter the Supervision time, then press ENTER.
Each enrolled wireless device will send a supervisory
signal to the Receiver at regular intervals. If the Recei-
ver does not receive the signal within the time program-
med in the Supervision window, it will generate a
supervisory fault (Lost wireless zone).
+
NOTE: You must enter two digits for the hours and
2 for the minutes, (e.g. To program 3 hours and 30
minutes, enter 0330).
Zone contr. time
hh.mm
4. Set this option for the Supervised Wireless Zones
ONLY(refer to "Supervised" under "Wireless" ). When
the Zone control time is elapsed from when the Rece-
iver has received the signal that each wireless zone
should send, the control panel does not allow the ar-
ming if the "Disable arming on wireless zones fault"
option is enable (See Option, page 75). Valid entries:
15 minutes (at default) to 2 hours (in 15-minute steps).
Options
Jam disable
5. Using ON or OFF, respectively, enable or disable the
RF Jamming detection option, then press ENTER.
n Vox board
This Control panel can manage the K3/VOX2 Voice bo-
ard. It is not necessary to enrol the Vox board manually,
the
as this will be done automatically by the Control panel.
However, it may become necessary to unenrol the Vox
board (e.g. To clear Trouble signalling), in such cases,
using A or B, select the Vox board option.
Configuration
Vox
Board
1. Press ENTER:

Vox Board

Not present
2. Press OFF, then press ENTER.
02.30
00.15
X