  • Page 1 EXPANDABLE MULTIFUNCTION CONTROL PANEL INSTALLATION MANUAL Vol.2 ® ISO 9001 ISO 9001 ISO 14001 ISO 14001 OHSAS 18001 OHSAS 18001 9105.BNT1 IT-52587 9191.BNT2 IT-52588 9192.BSEC IT - 60983...
  • Page 2 For spe cific in for ma tion see: www.bentelsecurity.com/en/environment.htm BENTEL SECURITY srl. re ser ves the right to chan ge the tec hni cal spe ci fi ca tions of this pro duct wit ho ut prior no ti ce.
  • Page 3: Table Of Contents

    TABLE of CONTENTS KEYPAD OPERATIONS Dialler Dig. co mu ni cat. Introduction Answe ring Ma chi ne Using the key pad Vo i ce mes sa ges Accessing the Installer menu Teleservice Exi ting the Instal ler menu Num. te le service Event logger Teleserv.
  • Page 4 Fi gu ra 1 Con trol Pa nel keypads: a) PREMIUM LCD; b) CLASSIKA LCD. KYO320...
  • Page 5: Keypad Operations

    KEYPAD OPERATIONS Introduction Using the key pad You can ope ra te your system from PREMIUM LCD and Read the fol lo wing sec tion ca re fully, to get an ove rall CLASSIKA LCD key pads, using the fol lo wing op tions: view of how to use the Fun ction keys.
  • Page 6: Accessing The Installer Menu

    In or der to al low you to pro gram the 32 Par ti tions of the When the system starts, on the di splay key pad is pos si - KYO 320, from the key pad, this pro gram ming sec tion ble to se lect the pro gram ming lan gua ges: has been di vi ded into 4 Par ti tion gro ups: 1st gro up —...
  • Page 7: Exi Ting The Instal Ler Menu

    You will not be able to se lect the Print from ... op - events in the Event Log ger. The KYO 320 Event log ger tion if the Print Log ger op tion is ena bled (re fer to can sto re up to 10,000 events.
  • Page 8: Zone Status

    Sta ir ca se Win dow This fun ction is pro vi ded by the op tio nal K3-PRT2 STBY UNBYPASSED Prin ter Inter fa ce. The Event log ger 4. Press ENTER aga in to view the Zone Re si stan ce (in The Event log ger is set up as fol lows: ohm, see the exam ple be low).
  • Page 9: Output Test

    Output test 44 se conds — for ave ra ge so und qua lity. The re cor ded mes sa ges can be as so cia ted with the Con trol pa nel This op tion will al low you to test the system Out puts. Inputs for Te lep ho ne ac cess, or sent to pre set te lep ho - From the Instal ler menu: ne num bers (Dial ler fun ction), or used as Answer mes -...
  • Page 10: Installer Pin

    Se conds fa ult, the re fo re, it can be used to chan ge the PINs of all Re ma i nin gSec.150 the ot her Instal ler Co des, and also its own (0200 at de - fa ult). Instal ler Co des 196, 197, 198 and 199 have Son sta tus, the re fo re, can chan ge the ir own PINs only (re - The se cond line of di splay shows the re ma i ning time to spec ti vely 0196, 0197, 0198, 0199 at de fa ult).
  • Page 11: User Codes

    Ø For full de ta ils on User Code pro gram ming, re fer to You can not as sign de fa ult PINs (re fer to Ta ble 10 on page 38). “Code Type” un der “Con trol Pa nel Pro gram ming”. To pro gram the User code pa ra me ters, ca re fully work thro ugh the fol lo wing steps.
  • Page 12: Digital Keys

    The top line of the di splay will show the ID num ber of the clu ded) for KYO 320, it will be co me the sole Fat her first Re a der in the con fi gu ra tion, whi le the bot tom line Code of it self.
  • Page 13: Program Panel

    Program Panel 6. Use A or B to con ti nue en rol ling. Accep tan ce will be con fir med by the fol lo wing mes sa ge: The Con trol pa nel pa ra me ters can be pro gram med via ENROL WIRELESS key pad, re fer to the “PROGRAM PANEL”...
  • Page 14: Activating Wireless Detectors

    Wi re less de tec tors sho uld not be lo ca ted in pla ces that Under cer ta in cir cum stan ces, the Con trol pa nel is give “bad” test re sults. una ble to de tect chan ges, the re fo re, will not up da te the system Key pads.
  • Page 15: Release

    Release If the key pad di splay is ope ra ting pro perly, it will show the let ters A to P on the top and bot tom line. If the LEDs I, a, G and M are ope ra ting pro perly, they will blink The Re le a se op tion will al low you to view of the Con trol pa nel fir mwa re re le a se.
  • Page 16 If the IP board (K-NET mo du le) has been con fi gu - red in the system, the di splay will show the cor re - spon ding IP ad dress. KYO320...
  • Page 17: Program Panel

    PROGRAM PANEL Configuration The Pro gram Pa nel op tion will al low you to pro gram all the pa ra me ters which de ter mi ne system ope ra tion. Re fer to “PROGRAMMING” in the INSTALLATION MANUAL The Con fi gu ra tion sec tion is di vi ded into dif fe rent pro - for the de scrip tion of the fol lo wing pa ra me ters: gram ming sec tions: Key pads, Re a ders, Input ex pan -...
  • Page 18: Led Keypads

    To unen rol a Key pad (de le te from the Con fi gu ra tion), If you ena ble the Part. Fast View op tion, me mory of Par ti tion Alarm and Tam per events will be si gnal led press OFF.
  • Page 19: Input Expanders

    n Input Expanders Ev. on red LED Even t n. ---- From the Con fi gu ra tion menu, using A or B, se lect the Input Expan ders op tion. To as so cia te an event with the Red LED (en ter the Event ID num ber (re fer to the EVENT co lumn in the Con fi gu ra tion “Events-Actions”...
  • Page 20: Powerstation 001

    To unen rol an Out put Expan der (de le te from the Con fi - Con fi gu ra tion Vector-RX module gu ra tion), press OFF. 5. Press ESC to go back to the Con fi gu ra tion menu. 1.
  • Page 21: Log Printer

    n Log Printer Zones Wired zones From the Con fi gu ra tion menu, using A or B, se lect Log Prin ter. Using A or B, se lect Wi red Zo nes or Wi re less Zo nes. Con fi gu ra tion Log Printer Zones Wireless zones...
  • Page 22: Programming Alarm Zones

    n Programming Alarm zones 9. press ENTER. Work ca re fully thro ugh the fol lo wing steps. Cycles Zone Type Repetitive Instan t 7c. Enter the re qui red num ber of cycles, or en ter all ze - 7a.
  • Page 23 For Alarm zo nes — the Par ti tion pa ra me ter de ter mi nes 15. Using A or B, se lect the re qui red Thre shold: Low, the par ti tions the zone be longs to, and thus its ope ra ting Mid, High, en ter the va lue (e.g.
  • Page 24: And-Zone Groups

    spec ti vely, to ena ble or di sa ble the re spec ti ve at tri bu te. Timeout Disabled The di splay will show the at tri bu te sta tus: “û” me ans Acti ve, “-” NOT ac ti ve. 14b.Enter the Inac ti vity Time (re fer to “Inac ti vity”).
  • Page 25: Outputs

    Press ENTER: press ENTER. Oscil la tion None Only Out puts 1, 2 and 3 of KYO 320 can be pro - gram med as Su perv.norm.clo. 12. Using A or B, se lect the Half Cycle of the oscil la - Follow tion.
  • Page 26: Partition

    Ci cles Auto arm timeout Nu mber Min. 13. Using A or B, set the num ber of Cycles for the Out - 8. Enter the time (in steps of 1 mi nu te) of the Auto-arm put con cer ned. The Cycles can be set for the Mo no sta - ti me o ut si gnal.
  • Page 27: Keys/Card

    Armed Mess.n --- 6. Using ON or OFF, re spec ti vely, ena ble or di sa ble the None di gi tal key con cer ned, then using A or B, se lect the Pa - trol at tri bu te. 15.
  • Page 28: Code Types

    WLS Key NOTE: If, at step 3 (User type), you se lect a User Wireless Key 001 type (co des 1 thro ugh 16) go to “User Code Types”. If you se lect an Instal ler type (co des 17, 18 and 19) go to “Instal ler Code Types”.
  • Page 29: Instal Ler Code Types

    Press ON or OFF, re spec ti vely, to ena ble or di sa - ble the fun ction con cer ned (“û” me ans ena bled, and “-” me ans di sa bled). Press ENTER to go to the next Option Ta bel la 3 KYO 320 Pa nel events sec tion. EVENTI...
  • Page 30 Ta bel la 4 Ge ne ric events (Con ti nu ed) for KYO320 Warning mains failure on Power 0984 station 0985 EVENT Warning low battery on Power station 2643 Warning power trouble on Power Test 0986 station 2643+n Reset on partition no. Battery not connected on Power 0987 2676...
  • Page 31: Events - Actions

    event ends (en ter all ze ros for NO ac tion), then using A EVENTO or B, se lect Dial ler On. 3415 Memo message present Event 0001 3416 B-NET module missing Dial ler On 3417 Lan Link missing 3418 IP receiver missing 7.
  • Page 32: Telephone

    Telephone lep ho ne num ber, press and hold 1 un til the key pad emits a beep. The Te lep ho ne op tion will al low you to se tup the Con - trol pa nel Pho ne bo ok, the te lep ho ne line pa ra me ters If you wish to in clu de pound (#) or star (*) in the te - and the Answe ring machine.
  • Page 33 Dial ler num bers spec ti vely, to go to the next or pre vio us Dial ler mes sa ge Nu mber (mes sa ge 1, 2, 3, 4 or 5). Using A or B, se lect the Vo i ce mes sa ge for the se lec ted Dial ler mes sa ge.
  • Page 34: Dig. Co Mu Ni Cat

    10d. Using A or B, se lect the Dial, Ti me o ut or Vo i ce Pro to col ADEMCO SLOW on line op tion, then press ENTER. Re fer to the re spec - ti ve pa ra graph for in struc tions. 7g.
  • Page 35: Answe Ring Ma Chi Ne

    Vo i ce mes sa ges Even t code Code 1.Using A or B, se lect the Vo cal mes sa ges op tion. 9h. Enter the Event code (re fer to “Code”) of the ac tion PROGRAMMING be ing pro gram med, (This is not va lid for Con tact ID, Vocal messages SIA and SIA over B-NET pro to cols) then press ENTER to go back to step 5h.
  • Page 36: Num. Te Le Service

    nan ce call or Vi gi lan ce call, then press ENTER and 5c. Press ON or OFF, re spec ti vely, to ena ble or di sa ble re fer to the re spec ti ve pa ra graph. the Cal lback op tion.
  • Page 37: Central Station Call

    Option sec tion 2 5h. Enter the key pad mes sa ge for the Instal ler Ma in te - Block ist.code - nan ce Re quest memo (re fer to “Ente ring a text” un der “Using the Key pad”), then press E to go back to step 3. 7.
  • Page 38: Default Pin

    3. Enter the Over ti me length (in mi nu tes), then press Disab.False Key Disable false key event ENTER to go to the next pa ra me ter. Va lid en tries: 0 Disable arming on wireless thro ugh 60 mi nu tes. NoArmReceivLost receiver lost Max over ti me n.
  • Page 39: Appendix

    APPENDIX n Installation K3/VOX2 Voice Board Work ca re fully thro ugh the fol lo wing steps (see Fi gu re 2 Di scon nect the Ma ins and bat tery po wer be fo re and Fi gu re 2 in the Instal la tion Ma nual Vol.1). star ting the in stal la tion pro ce du re.
  • Page 40: Manual Selection

    Ø All the Out puts of the M-IN/OUT Expan der, pro gram - or si mi lar. The in stal la tion in struc tions can be fo und in the MINI-BOX pack age. med as Expan der with 6 Out puts, as such must be Re ser ved Out puts (ma nual), Bi sta ble, Nor mally The Mi crop ho ne and Lo ud spe a ker sho uld be ho u - Open;...
  • Page 41: Manual And Auto-Select Mode

    n Manual and Auto-select mode Sof twa re Out puts 7, 8, 9 and 10 (ava i la ble for this ap - pli ca tion) must be: Mo no sta ble and Nor mally open Ma nual and Auto-se lect Li sten-in can be in te gra ted. (DO NOT pro gram the se Out puts as Re ser ved).
  • Page 42: K3/Prt2 Printer Interface

    n Connecting the Printer K3/PRT2 Printer Interface If you pre fer to cha se the lead, use a plug-free ca ble (re - Di scon nect the Ma ins and bat tery po wer be fo re fer to Ta ble 11 for the wi ring spe ci fi ca tions and see also star ting the in stal la tion pro ce du re.
  • Page 43: Wireless Receivers

    Wireless Receivers DESCRIPTION 118 Spring catch slots (2) The VRX32-433 and VRX32-868 Re ce i ver (ac ces sory 119 An chor screw lo ca tions (3 x ø 4.6 mm) item) will al low your system to ma na ge up to 32 Wi re - 120 An tennas (2) less de tec tors (PIRs, Ma gne tic Con tacts, Smo ke de tec - 121 Mi cro pro ces sors (2)
  • Page 44: Connecting The Receiver

    6. Pla ce the backpla te in the pro po sed pla ce ment, pull the wi res thro ugh the wire entry 125, then se cu re the backpla te to the wall (use an chor screws). 7. Com ple te the con nec tions on the ter mi nal bo ard 127 (re fer to “Con nec ting the Re ce i ver”).
  • Page 45: K-Net Module

    K-NET MODULE DESCRIPTION 129 Indi ca tor light (S) for con nec tion spe ed: Instal ling the K-NET Mo du le (Re fer to K-NET ma nual), off = 10 Mbps; on = 100 Mbps will al low you to con nect se ve ral Con trol pa nels to the 130 Con nec tor for the Con trol panel link.
  • Page 46: Technical Specifications

    2. Fix the Mo du le to the base of the con trol unit using 5. Re set the po wer supply to the Con trol Pa nel (see the screws sup plied, ma king sure it is cor rectly ali - “Con nec ting Po wer Supply”...
  • Page 47 EVENT CONTACT ID CL. CODE GROUP ZONE TYPE Burglar alarm on partition part. no. BA/BR part. no. Generic alarm on partition part. no. BA/BR part. no. Tamper alarm on partition part. no. TA/TR part. no. Generic+Tamper alarm on partition part. no. TA/TR part.
  • Page 48 EVENT CONTACT ID CL. CODE GROUP ZONE TYPE Warning low battery on Power station YT/YR 0000 Warning power trouble on Power station YM/YR 0000 Battery not connected on Power station YP/YQ 0000 Battery charger trouble on Power station YP/YQ 0000 Switching not connected on Power station YP/YQ 0000...
  • Page 49 EVENT CONTACT ID CL. CODE GROUP ZONE TYPE Real time of zone zone no. UA/UH 0000 zone no. Test RP/UX 0000 Reset on partition part. no. BC/UX part. no. Reset on panel BC/UX 0000 Super key UX/UX 0000 Key F on KeyFob UX/UX 0000 Key A on KeyFob...
  • Page 50: Dbma Na Ger

    fre quen cies. The fre quency shift is usually 170 Hertz, and the two fre quen cies are as so cia ted with 0 and 1 of the bi nary di git which tran smits the fol lo wing data: Ø...
  • Page 51: Tools

    n Tools Help Menu To ols com mand opens To ols win dow, as shown be low. Help shows this file for a fast re fe ren ce. Data path Se lect the so ur ce dri ve and fol der con ta i - ning the da ta ba se to be re struc tu red/re in de xed.
  • Page 52 ® BENTEL SECURITY s.r.l. Via Gab bia no, 22 Zona Ind. S. Sco la sti ca 64013 Cor ro po li (TE) -ITALY Tel.: +39 0861 839060 Fax: +39 0861 839065 e-mail: in fo ben tel se cu rity@tycoint.com http:www.ben tel se cu rity.com...