Auto-Arm Timeout This field will allow you to program
the Automatic Arm pre-alert period.
For example, if the Timer is set to Arm Partition no. 1 at
17:45 p.m. with a 15-minute Auto-Arm Timeout, the
system will generate the Autoarming warning parti-
tion no. 1 event at 17.30, and will signal the start of the
pre-alert period. The pre-alert signal will warn anyone
on the premises that the system is about to Arm. During
the pre-alert phase the system will accept Overtime Re-
quests. If no valid Code is entered during this period,
the system will Arm as programmed.
The event will end when the programmed Auto-Arm
Timeout expires or when the Partition Arms after an
Overtime request.
Valid entries: 0 through 240 minutes, in 1-minute steps.
If you set 0, there will be no warning.
If you enter a higher value than the maximum, it will be
converted automatically to 240 minutes.
Auto-Arm Signal If this option is enabled (ü) for the Par-
tition (Enabled at Default), the Partition Keypads will emit
an audible signal (beep) during the entire pre-alert period.
Patrol Time This programming field will allow you to
set the Patrol Time. If the system is disarmed by a User
Code with the Patrol attribute (refer to "Patrol Code" un-
der "Keypad Codes — User"), it will rearm automatically
when the programmed Patrol Time expires.
Valid entries: 0 through 254 minutes in 1-minute steps.
Default setting: 10 minutes.
Autoreset on Arming If this option is enabled (at de-
fault), the system will Reset Partition Alarms each
time it is Armed (refer to "Reset Partition Alarms" under
"Keypad Codes — Code Types").
Timer Associated Arming This option provides the
system with an Arm command filter. If a Timer window
is associated with a Partition, the system will carry out
commands to Arm the Partition concerned ONLY when
the respective Timer window is running (refer to
"Scheduler - Timers").
Timer Associated Disarming This
provides the system with a Disarm command
filter. If a Timer window is associated with a Parti-
tion, the system will carry out commands to Dis-
arm the Partition concerned ONLY when the re-
spective Timer window is running (refer to "Sched-
uler - Timers"). However, if the Disarm with
Alarm in memory option is enabled, it will be
possible Disarm the Partition in the event of viola-
tion (Alarm or Tamper) during the Timer window.
Confirm alarm If this option is enabled and a
zone triggers Alarm status, the system will
start the respective Confirm alarm timer
window but will not generate a Partition bur-
glar alarm. If another zone alarm occurs
(triggered by a different zone) while the Timer
window is running, the system will generate a
Partition alarm.
KYO 320
Confirm alarm timer This field will allow you to pro-
gram the Confirm alarm timer window (necessary
when the Confirm alarm option is enabled) which deter-
mines the Partition alarm delay. This feature will allow
the system to trigger a Partition alarm only when two or
more zone alarms (triggered by different zones) occur
during the running window.
Disarm with Alarm in memory If this option is en-
abled, it will be possible to override the Partition Timer
and Disarm the Partition in the event of violation (Alarm
or Tamper in memory), even when the Timer window is
running (refer to Timer associated Disarming). This
feature will allow users to disarm Timer controlled Parti-
tions which under normal circumstances (unviolated)
cannot be disarmed. The permitted values range from a
minimum of 30 to a maximum of 60 minutes.
Partition Armed Voice Message This option will al-
low you to select the voice message which will answer
status enquiries over-the-phone (DTMF) when the Par-
tition concerned is armed.
allow you to select the voice message which will answer
status enquiries over-the-phone (DTMF) when the Par-
tition concerned is disarmed.
+

Telephone

The Telephone page will allow you to program:
Ø the Telephone numbers for the Digital Communica-
Ø Telephone line parameters;
Ø the Answering Machine parameters.
option
Figure 32 Telephone page
PROGRAMMING FROM THE PC
Partition Disarmed Voice Message This option will
The "Partition Armed" voice message will apply to
all arming types: Stay; Away, Stay 0 Delay.
tor, Dialler, Auxiliary Communicator and Teleservice
facilities;