Accessories - Bentel Security KYO 320 Installation Manual

Expandable multifunction control panel
Hide thumbs Also See for KYO 320:
Table of Contents

Advertisement

Ø the Event details in the Log
TYPE — Fault chrg.pw.s
EVENT ID. — The Power Station label (Description)
Disconnected Power supply module
by:
Ø the Switching not connected on Power station
event (refer to "Events-Actions" section)
Ø the ON status of the G LED on the keypads, and the
Swtch.disc.pw.s message (refer "View Trouble
Mode" in the USER MANUAL)
Ø the Event details in the log
TYPE — Swtch.disc.pw.s
EVENT ID. — The Power Station label (Description)
Current draw of a Power station output that exceeds the
maximum will be signalled:
Ø the Short circuit output ½/3 on Power Station
event (refer to "Events-Actions" section)
Ø the ON status of the G LED on the keypads, and the
Out. short pw.s message (refer "View Trouble
Mode" in the USER MANUAL)
Ø the Event details in the log
TYPE — Out. short pw. s
EVENT ID. — The label (Description) of the respec-
tive Power Station
AGENT: Output number
n Accessories
The Accessories page will allow you to set up the Wire-
less Receiver, Auxiliary Communicator, Voice boards
and Printer interface.
Wireless module The Present option MUST BE
ENABLED, if a VectorRX Receiver is connected to the
Control Panel KEY bus.
+
The Wireless module option must be enabled
manually, otherwise, it will be impossible to pro-
gram the wireless devices (refer to "Wireless").
Transmission trouble between the Control Panel and
Receiver (due to Fault or Tamper) will be signalled by
an X above the s icon on the Keypad, and by the
Warning wireless device event.
+
Receiver Trouble and Lost BPI devices will be sig-
nalled in the same way ( X above the s icon on
the Keypad. If the signal is due to Receiver Trou-
ble, the Keypad will display the Receiver Lost
message in the TYPE field in the Events Log (refer
to "Events Log" in the KEYPAD PROGRAMMING
MANUAL).
Disable the Present option to clear the Receiver Trou-
ble warnings.
5 The Power station will disconnect the Power supply module if its output voltage reaches 0.5V above the preset
value.This operation will prevent damage to the peripherals. The power to the peripherals will be provided by the
Power station battery. If the Power station is not equipped with a Thermal probe, the preset output voltage will
be 13.8 V. If the Power station is equipped with a Thermal probe, the output voltage will depend on the probe
temperature.
KYO 320
5
will be signalled
PROGRAMMING FROM THE PC
Time Supervision Zones This programming field will
allow you to program the supervisory time for the Su-
pervised Wireless Zones (refer to "Supervised" under
"Wireless" ). Each wireless zone should send a supervi-
sory signal within a programmed interval. If the Re-
ceiver does not receive the signal it will generate a Lost
wireless zone event.
Valid entries: 2 hours and 30 minutes (at default) to 24
hours (in 15-minute steps).
Zone control time Set this option for the Supervised
Wireless Zones ONLY(refer to "Supervised" under
"Wireless" ). When the Zone control time is elapsed
from when the Receiver has received the signal that
Each wireless zone should send the control panel
does not allow the arming if the "Disable arming on wire-
less zones fault" option is enable (See Option, page 75).
Valid entries: 15 minutes (at default) to 2 hours (in
15-minute steps). When a LCD keypad is arming, the
zones, that haven't sent signals in the programmed time
(Wireless delinquency Zones), are shown.
GSM Communicator Not present-Present-FUTURE
USE.
Disable Jamming If the system detects RF jamming,
and this option is DISABLED (at default), it will be sig-
nalled by an X above the b icon on the Keypad, and by
the Tamper wireless device event.
+
Jamming and BPI Device Tamper will be signalled
by X above the b icon on the Keypad. Jamming
and Receiver Tamper will be signalled by the Tam-
per wireless device event. If the signal is due to
Receiver Tamper (jamming, opening or removal)
the WLS Tamper event will be logged.
VOX board The Control Panel will enrol the Voice
board as soon as it is connected to the Keybus. Trans-
mission trouble between the Control panel and Voice
Board (due to Fault or Tamper) will be signalled on the
G LED (ON).
+
The G LED signals several different Trouble
events. If the signal is due to loss of the Voice
Board, the Keypad (in View Trouble Mode) will
show the Vox Board Lost message (refer to
"View Trouble Mode" in the USER'S MANUAL).
Disable the Present option to clear the Voice board
Trouble warnings.
Print Log If this option is enabled the Control panel will
printout the events as they occur (real-time printout).