Ø the programming session ends (i.e. when you exit
the Installer Menu or complete downloading via the
PC);
Ø the Zone is Unbypassed.
+
A Zone that signals a persistent Alarm condition
(e.g. due to Trouble conditions) will generate one
Alarm cycle ONLY. It will be unable to generate fur-
ther cycles until the Alarm counter has been
cleared.
n Partitions
This table will allow you to assign the Alarm and Com-
mand Zones to the Partitions.
For Alarm Zones — The selected Partitions will deter-
mine which User Codes, Digital Keys/Cards and Operat-
ing Times will be associated with the Zone. Each Alarm
Zone can be assigned to more than one Partition.
+
If the Zone is a Delayed Zone (Entry Delay, Path,
Exit Delay or Last Exit Delay), the system will apply
the longest Entry Delay, Exit Delay or Last Exit De-
lay of all its Armed Partitions.
For Command Zones — The selected Partitions will deter-
mine which Partitions the Zone will be able to control. Each
Command Zone can operate on more than one Partition.
Full Arming Alarm If this option is enabled, the Zone
will be able to generate the Alarm on Zone event ONLY
when ALL of its Partitions are Armed.
If this option is disabled, the Zone will be able to gener-
ate the Alarm on Zone event even when AT LEAST
ONE of the Partitions it is assigned to is Armed.
n Sensitivity
The system will signal Zone Alarm status when the volt-
age on the Zone terminal exceeds the Alarm threshold
for the programmed interval (Within), and/or number of
times (Pulses). This section will allow you to program
amount of time (Length) and/or the number of times
(Pulses), as follows.
Standard This field will allow you to set the
number of Pulses that will trigger Alarm status.
Valid entries: 1 to 3 pulses from 100 ms (0.1
seconds) through 1000 ms (1 second) in steps
of 100 ms (0.1 seconds).
If you set more than 1 Pulse, you will be able to
set the Within time (i.e. the interval within which
the programmed number of Pulses must oc-
cur), and select whether the system will signal
Zone Alarm when:
— Pulses are detected within the set time
(Alarm for n pulses within t Sec., where n
stands for the number of Pulses and t the pro-
grammed Within time), or when:
— 1 pulse is detected which is longer than the
programmed Within time (OR single pulse
with length > t Sec., where t stands for the pro-
grammed Within time).
KYO 320
Low This field will allow you to set the minimum Pulse
length.
If you select Step 500 ms, you will be able to set a Pulse
length of 0.5 through 32 seconds in 0.5 second steps.
If you select Step 30 sec., you will be able to set a
Pulse length of 30 through 1920 seconds (32 minutes)
in 30 second steps.
+
n Voice Messages
This feature is provided by the K3/VOX2 kit (optional
Voice Board + Speaker). If this optional feature is avail-
able, you will be able to assign two voice messages to
the Zone. These messages will allow the User to make
status enquiries (with voice answer) over the phone.
The Voice Messages can be recorded, played and de-
leted at the Keypad (refer to "Voice Messages").
Standby This field will allow you to select the Message
which will be played when the Zone is in Standby status.
+
Alarm This field will allow you to select the Message
which will be played when the Zone is in Alarm, Tamper
or Short Circuit status.
+
Default Code In Contact ID and SIA protocols case,
the associated code changes with Alarm Types (See
Alarm Zones). In this way, a Fire Zone (for example) will
be associated to a particular code that will be different
from a Duress Zone or 24h Zone.
Figure 27 AND Zones Page
PROGRAMMING FROM THE PC
If you select the Step 30 sec. option, the Control
panel will round off the Pulse length to the nearest
5 seconds. For example, if you set 30 seconds, the
Control panel will trigger an Alarm when it detects a
Pulse between 25 and 30 seconds.
If no message is selected, Standby status will be
signalled by a Beep.
If no Voice Message is selected, Zone Alarm will
be signalled by two Beeps.