Release; Keypad; Reset Warning Lithium; Serial Ports - Bentel Security KYO 320 Installation Manual

Expandable multifunction control panel
Hide thumbs Also See for KYO 320:
Table of Contents

Advertisement

Release

The Release option will allow you to view of the Control
panel firmware release. From the Installer menu:
INSTALLER MENU
Event logger
1. Using A or B, select the Release option.
INSTALLER MENU
Release
2. Press ENTER.
rev. firmware:
KYO320 -
2.06
3. To go back to the Installer menu, press ESC.

keypad

The keypad option will allow you to test the keypad di-
splay, LEDs and buzzer.
From the Installer menu:
INSTALLER MENU
Event logger
1. Using A or B, select the Test keypad option.
INSTALLER MENU
Keypad
2. Press ENTER:
Keypad
Language
3. Press ENTER:
1:<ITA>
2:ENG
3: ESP
4:FRA
is possible to select the programming languages: enter
the number which corresponds to language and then
press ENTER.
Keypad
Language
4. Using A or B, to select:
Keypad
Test keypad
5. Press ENTER
ABCDEFGHIJKLMNOP
ABCDEFGHIJKLMNOP
KYO320
If the keypad display is operating properly, it will show
the letters A to P on the top and bottom line. If the LEDs
I, a, G and M are operating properly, they will blink
for several seconds. If the buzzer is operating properly,
it will emit three beeps.

Reset warning lithium

The Reset warning lithium option will allow you to cle-
ar the trouble signals generated by the RAM battery.
+
Under normal circumstances, the battery should
last about two years, after which it must be repla-
ced. This Control panel monitors the battery life —
starting from the last Reset Lithium battery ope-
ration, but DOES NOT monitor the battery charge.
From the Installer menu:
INSTALLER MENU
Event logger
1.Using A or B, select the Reset warning lithium.
INSTALLER MENU
Res.warn.lithium
2. Press ENTER:
INSTALLER MENU
The Keypad will indicate that the operation has been
caried out and then will go back to step 2.

Serial Ports

From the Installer menu:
1. Using A or B, select the Serial Ports option.
INSTALLER MENU
Serial Ports
2. Press ENTER. The Keypad will show the BAUD
RATE value and, by means of an X, the presence of the
respective Parity Bit. The first line will show the speed of
the serial communication between the Control panel
and the local PC. The second line will show the speed
of the serial communication between the Control panel
and the PC used for remote Teleservice.
57600
1200
3. To go back to the Installer menu, press ESC.
+
If the IP board (K-NET module) has been configu-
red in the system, the display will show the corre-
sponding IP address (see page n. 46).
KEYPAD OPERATIONS
Done!
x
x
15

Advertisement

Table of Contents
loading

Table of Contents