  • Page 1 Unit MAIN UNIT MANUAL ® MADE ITALY...
  • Page 2 The Manual Release Number is shown at the bottom of the last page, between the Code and Date, and indicated in the figure below. Manual Release Number ISTUCBLEUNKYO 190303 P70 Code Date BENTEL SECURITY srl reserves the right to modify the technical specifications of this product without prior notice.
  • Page 3: Table Of Contents

    ® ® ABLE OF ONTENTS Section 1 - Introduction ..........5 Certification Formalities ..............5 General Features ................5 About the System ................7 Control panel Versions ..............7 Components and Accessories ............8 Technical Specifications ..............9 Section 2 - Identification of Components ....10 KYO 4 M –...
  • Page 4 ® ® Multifunction Control Panel Section 4 - Installing the Control Panel ....... 25 Mounting the Control Panel ............. 25 Opening and Closing the Control Panel .......... 26 Section 5 - Installing the NC2/VOX ......28 General Features ................28 Additional VOX-REM Modules ............
  • Page 5: Section 1 - Introduction

    ECTION NTRODUCTION Certification Formalities The KYO-Unit series can be purchased as out-of-the-box Control pan- els, or as separate package components. Bentel Security S.r.l declares that KYO-Unit separate package components comply with the essen- tial requirements and other relevant provisions of Directive R&TTE 1999/5/CE —...
  • Page 6 ® ® Multifunction Control Panel Expandable to 14 x 150 mA Outputs for KYO 32 series Expandable to 16 x 150 mA Outputs for KYO 32 G series Metal box (Model M) or Plastic Box (Model P) Accepts Conventional Fire Detectors, and provides restoral facility Supports up to 8 Keypads Supports up to 16 Readers (ECLIPSE and/or PROXI) Digital Dialler...
  • Page 7: About The System

    ® ® Section 1 - Introduction About the System The Control panel The Control panel is made up of a Control Unit, Digital Communicator and Modem. It can be controlled from remote Keypads and/or Digital Key/Card Readers. The Digital Communi- The Digital Communicator can call up to 8 Telephone numbers for Teleservice cator and communication to Central Stations.
  • Page 8: Components And Accessories

    ® ® Multifunction Control Panel Components and Accessories T able 1.3 - Components and A ccessory Items Code Description K4 - K8 - K32 PCB for KYO4, KYO8 and KYO32 K8G - K32G PCB for KYO8 G and KYO32G BOX-M Metal box for M Models BOX-P Plastic box for P Models...
  • Page 9: Technical Specifications

    ® ® Section 1 - Introduction Technical Specifications Table 1.4 shows the Technical Specifications of the various Control panels and accessory items. Table 1.4 - Technical Specifications Control Panels Values KYO 4 M KYO 4 P Specifications KYO 8 G P-SW1 KYO 8 G P-SW2 KYO 8 M KYO 8 P...
  • Page 10: Section 2 - Identification Of Components

    ® ® Multifunction Control Panel 2 - I ECTION DENTIFICATION OF OMPONENTS The numbers in boldface in square brackets [ ], in this and other Manuals relevant to this product, refer to the components described in this section. KYO 4 M KYO 8 M KYO 32 M 7 8 9a Figure 2.1 - KYO 32 M Control panel complete with NC2/VOX Voice Board (accessory item)
  • Page 11: Kyo 4 P Kyo 8 P Kyo 32 P

    ® ® Section 2 - Identification of Components KYO 4 P KYO 8 P KYO 32 P Figure 2.2 - KYO 32 Control panel complete with NC2/VOX Voice Board (accessory item)
  • Page 12: Kyo 8G P-Sw1 Kyo 32G P-Sw1

    ® ® Multifunction Control Panel KYO 8G P-SW1 KYO 32G P-SW1 Figure 2.3 - KYO 32G P-SW1 Control panel with NC2/VOX Voice Board (accessory item)
  • Page 13: Kyo 8G P-Sw2 Kyo 32G P-Sw2

    ® ® Section 2 - Identification of Components KYO 8G P-SW2 KYO 32G P-SW2 Figure 2.4 - KYO 32G P-SW2 Control panel complete with NC2/VOX (accessory item)
  • Page 14 ® ® Multifunction Control Panel Table 2.1 - Identification the Main Unit Parts Part Description Frontplate Screws (2) Locations (4) for backplate screws (Ø = 5 mm) Reverse locking PCB supports (see Figure 3.3) PCB location Tabs Locations (2) for PCB screws A rrester for BA Q35T12 Switching Power-Supply/Battery Charger Terminal Board DB-9 male connector for computer link...
  • Page 15: Status Leds (Only For 'G' Series Pcbs)

    ® ® Section 2 - Identification of Components Table 2.2 - Identification of the Switching Power Supply Components Part Description BAQ35T12 Switching Power Supply BAQ15 Switching Power Supply Mains LED (ON = Mains OK) Fine Adjustment Trimmer KST Jumper — this Jumper must be inserted, when a KST Thermal Probe is connected to the battery Auxiliary Terminals for system peripheral (Output = 13.8 Vcc) Screw to secure the Switching Power Supply to the backplate:...
  • Page 16 ® ® Multifunction Control Panel Figure 2.5 - KYO 8G and KYO 32G Status LEDs 35 36 Figure 2.6 - NC2/VOX Voice Board Components Table 2.4 - Identification of the NC2/VOX Components Part Description LOC-MIC Jumper: (at Default) - NC2/VOX Microphone Enabled LOC-MIC Jumper: - NC2/VOX Microphone Disabled REM-MIC Jumper:...
  • Page 17: Section 3 - Mounting The Components

    ® ® Section 3 - Mounting the Components 3 - M ECTION OUNTING THE OMPONENTS Introduction Please read this section to get an overall view of the steps involved in installing Control panels from the KYO Unit range. Boxes and Accessories Metal and Plastic boxes are available.
  • Page 18: Installing The Transformer And Mains Screw Terminal - Fused

    ® ® Multifunction Control Panel The Plastic Box (Order Code BOX-P) package includes the following parts: Plastic Box 18 Balance Resistors — 10 Kohm 1 x 40 cm Earth wire (Yellow-Green) without eyelet [13b] 2 Parker screws — 2.9 x 7.5 to secure the PCB 1 Parker screw —...
  • Page 19: Plastic Box

    ® ® Section 3 - Mounting the Components Mount the Transformer onto the 2 fixed screws (M3x10) on the backplate of the Metal box. Fit the eyelet terminal [13a] to the fixed screw (as shown in Figure 3.2a) then, using two hexagonal nuts, secure the transformer to the backplate. Connect the Transformer primary (RED wires) to terminals [N] and [L].
  • Page 20: Installing 'G' Series Pcbs (K8G-K32G)

    ® ® Multifunction Control Panel Metal box Insert the 4 reverse locking PCB supports [3a] into their locations on the backplate, then attach the PCB. If you are installing an NC2/VOX Voice Board, insert the supports (LEDs to the bottom) and then attach the NC2/VOX Voice board (see Figure 3.3).
  • Page 21: Installing The Switching Power Supply

    ® ® Section 3 - Mounting the Components Installing the Switching Power Supply Please read the following instructions to get an overall view of the steps involved in installing Switching Power Supplies in ‘G’ series Control panels (i.e. Control panels with K8G and K32G PCBs). Two Switching Power Supplies are available: BAQ15 (1.5 A) or BAQ35T12 (3 A) Installing BAQ15 Switching Power Supplies Work carefully through the following steps (refer to Figures 2.3 and 3.5).
  • Page 22: Earthing The Pcb

    ® ® Multifunction Control Panel Earthing the PCB The PCB must be earthed by means of the Earth wire ([13a], [13b] or [13c]), in order to protect it from electrical surges from the Telephone Line, and comply with Safety Regulations. Marking Ticket Once you have assembled the components, specify the type of Control panel that you have constructed.
  • Page 23: Connecting The Nc2/Vox Voice Board

    ® ® Section 3 - Mounting the Components The KST connection cannot be considered complete until the OVC-Link Wire [29b] (supplied with the Switching Power Supply) has been connected. NOTE: If you are connecting a KST thermal probe to a Control panel with a BAQ15 Power Supply, ensure that the BAQ15 on-board Jumper [22b] is inserted.
  • Page 24: Plastic Box

    ® ® Multifunction Control Panel CONTROL CONTROL CIRCUIT CIRCUIT BACKPLATE BACKPLATE (PCB) (PCB) GASKET [12] [12] Figure 3.6 - Installing the NC2/VOX Voice board in Metal box (Left) or Plastic box (Right) Connector B on the PCB. Plastic box 1. Slot the NC2/VOX board in the holder [12b] — LEDs to the top. 2.
  • Page 25: Section 4 - Installing The Control Panel

    ® ® Section 4 - Installing the Control Panel 4 - I ECTION NSTALLING THE ONTROL ANEL Mounting the Control Panel The Control panel must be mounted in a safe, dry place, close to the placement of command devices (Keypads, Readers, etc.). Once you have selected a mounting location and created a layout, ensure that you will be able to connect the Mains and Telephone line.
  • Page 26: Opening And Closing The Control Panel

    ® ® Multifunction Control Panel NOTE: In order to comply with the Safety Regulations in force, this product must be protected against electrical surges (e.g. from the Telephone Line), and therefore must, be connected to the Mains Earth line. The product warranty does not cover damage to the PCB caused by non-connection, or improper connection to a faulty Mains Earth line.
  • Page 27 ® ® Section 4 - Installing the Control Panel Table 4.1 - Description of the Terminals PCB Terminals Voltage Current Description Max. (A) K8G-K32G K4-K8-K32 Terminals for the BPI Device connections 1-2-3-4 13.8 [+][C][R][-] (Keypads, Readers, Expander, etc.) 5 [AS] 17 [AS] Balanced 10K Tamper Line –...
  • Page 28: Section 5 - Installing The Nc2/Vox

    ® ® Multifunction Control Panel 5 - I NC2/VOX ECTION NSTALLING THE The NC2/VOX Voice Board (Accessory Item) will allow you to record and send Voice messages to the programmed Telephone numbers. For the installa- tion instructions refer to Section 3 under ‘NC2/VOX’. General Features Voice synthesizer —...
  • Page 29: Record / Play Messages

    ® ® Section 5 - Installing the NC2/VOX NC2/VOX Jumper NOTE: If you connect a VOX-REM Module, you must set the jumpers on the Settings NC2/VOX as follows: LOC-MIC Open ( REM-MIC Closed ( LOC-SP Open ( REM-SP Closed ( - The NC2/VOX supports up to 4 additional VOX-REM Modules.
  • Page 30: Selecting Messages

    ® ® Multifunction Control Panel Table 5.1 - Selecting the Message Message No. 15 sec 15 sec 15 sec 15 sec 7 sec 7 sec 7 sec 7 sec Length LED 1 LED 2 LED 3 LED 4 Selecting Messages The Voice Board can record up to 8 Alarm messages.
  • Page 31: Programming

    ® ® Section 5 - Installing the NC2/VOX Programming Proper operation of the NC2/VOX Voice Board depends on Telephone and the Events pages (refer to ‘Programming from PC’ in the ‘INSTALLATION MANUAL’). Activation The Alarm messages will be triggered by their assigned events. When the Event occurs the Control panel will go through the following phases (see Figure 5.2): 1.
  • Page 32 ® ® BENTEL SECURITY S.r.l. - C.da Ravigliano, Z.I. S. Scolastica - 64013 CORROPOLI - TE - ITALY Tel.: +39 0861 839060 - Fax: +39 0861 839065 E-mail: info@bentelsecurity.com - http://www.bentelsecurity.com ISTUCBLEUNKYO 1.1 260603 P70...