Digital Keys can be enrolled at the Keypad (refer to
the KEYPAD PROGRAMMING Manual.
The Table on the left side of the Digital Keys page
shows the Keys the Control Panel can manage.
ü Select the required Keys:
Box checked (ü) = Key Enabled
Box empty = Key Disabled
Press the Select button at the bottom of the page to En-
able/Disable all the Keys.
+
The system will consider Disabled Keys as False,
even if they have been enrolled.
No. This is the Key ID Number.
Description This editable field (16 characters) is for
the Key label (e.g. User's Name). The label will identify
the key in all the operations it is involved in.
The parameters of the key (selected on the left side of
the page) can be programmed on the right side of the
Keys page, as follows.
Enable on Partitions This line will allow you to assign
the Key to the Partitions.
Box checked (ü) = the Key is Enabled on the corre-
sponding Partition
Box empty = the Key is Disabled on the corresponding
Partition
To DISABLE the Key on all the Partitions: click the Par-
titions button (bottom of page) then select None.
To ENABLE the Key on all the Partitions: click the Parti-
tions button (bottom of page) then select All.
To toggle the current Enabled/Disabled status of the
Key: click Partitions button (bottom of page) then se-
lect Invert selection.
Stop Alarms If this option is enabled, the Key will be
able to stop Control panel Alarms (refer to "Stop
Alarms" under "Codes - Code types").
Stop Partition Alarms If this option is en-
abled, the Key will be able to stop Partition
Alarms (refer to "Stop Alarms" under "Codes -
Code types").
Clear Call Queue on disarming If this option
is enabled, the Key will be able to stop outgoing
Alarm calls (refer to "Clear Call Queue upon
Disarming" under "Codes - Code types").
Associated Timer If this option is enabled,
the Key will be able to perform its programmed
functions ONLY during its Timer slots (refer to
"Scheduler - Timers").
n Allowed Operations
This section of the Digital Keys Page will allow
you to set up the amount of times a Key can op-
erate the system (i.e. perform Arm/Disarm in
KYO 320
Away, A and B Mode operations) before it is locked out
automatically.
Unlimited If this option is enabled, the Key will be able
to perform an unlimited number of operations. If this op-
tion is disabled, the required number of operations can
be programmed in the Operations field.
Maximum Operations This programming field will al-
low you to program the amount of times the Key can op-
erate the system (accepted values: 1 to 254).
The system will disable the Key automatically when the
'Maximum Operations' counter reaches its limit.
The 'Maximum Operations' counter can be cleared
and the Key re-enabled by entering a valid User Code
(refer to "Enable Key Control" under "User Code Type").
n Attributes
Patrol If this attribute is enabled, the Key will be able to Dis-
arm and Re-arm the Control panel during the programmed
Patrol Time. If a Partition is disarmed by a Key with the Pa-
trol attribute, the Partition will Re-arm automatically when
the programmed Patrol time of the Partition concerned ex-
pires (refer to "Patrol Time" in the "Partitions" section).
Arm only If this attribute is enabled, the Key will be able to
Arm the Control panel ONLY.
Disarm only If this attribute is enabled, the Key will be
able to Disarm the Control panel ONLY.
n Enable on Key Reader
The "Enable Key Reader" table will allow you enable the
code concerned on the Key Reader (32 Readers for
KYO320).

KeyFobs

Systems with VectorRX-8 or VRX32 serie Receivers can
manage up to 16 keyFobs (up to 32 with VRX32 series).
Figure 50 Wireless key page.