Partition

From the Programming menu:
1. Using A or B, select the Partitions option.
PROGRAMMING
Partition
2. Press ENTER:
Partition n. 001
Partition
3.Press A or B to select the required partition, then
press ENTER.
Description
Partition
4. Enter the partition label (refer to "Editing a text" under
"Using the Keypad"), then press ENTER.
Entry time
mm.ss.
00.30
5. Enter the time (in minutes and seconds) the system
must wait before generating an Alarm on zone event
after violation of an Entry delay zone, then press E.
Exit time
mm.ss
00.15
6. Enter the Exit time (in minutes and seconds). Viola-
tion of an Armed Exit Delay zone will generate the pro-
grammed Exit time. If violation ends before the Exit
time expires the zone will not generate the Alarm on
zone event.
Press ENTER to continue.
Last exit time
mm.ss
00.15
7. Enter the Last exit time (in minutes and seconds),
then press ENTER. Violation of a Last exit zone will
generate the Last exit time of the partition the zone be-
longs to. This feature will allow the system to Arm as
soon as the Last exit time expires. Valid entries for
Entry, Exit and Last exit times: 0 minutes 0 seconds
through 59 minutes 59 seconds.
26
01
001
001
Auto arm timeout
Min.
010
8. Enter the time (in steps of 1 minute) of the Auto-arm
timeout signal.
Valid entries: 1 through 240 minutes.
Press ENTER to continue.
Options
AutoArm del.sigx
9. Using A or B, select the AutoArm del. sig. (refer to
"Autoarm Signal"), Autoreset (refer to "Autoreset on
Arming"), Disarm with mem. (refer to "Disarm with
alarm memory") or Confirm Alarm (refer to "Disarm
with alarm memory") then, using ON or OFF, respecti-
vely, enable or disable the option concerned, then
press ENTER.
If you select the Confirm Alarm option, you must enter
the respective Confirm time (in steps of 1 minute).
Valid entries: 30 to 60 minutes.
Confirm time
Sec.
0060
Press ENTER to continue.
Negligence time
None
10. Enter the Negligence time (in steps of 1 minute). If
the Negligence time of a partition expires, the Control
panel will generate the respective Negligence event.
The Negligence time of a partition will refresh each
time the partition is Armed.
Valid entries: 1 to 60000 minutes, or enter all zeros to
set None.
Press ENTER to continue.
Ext.r.toArmDelay
min.
05
11. Enter the Extended Ready-to-Arm delay, then
press ENTER.
Patrol Time
Min.
00010
12. Enter the relevant Patrol Time, then press ENTER.
InhibitArming---
None
13.Using A or B , select the Timer that will filter Arming
commands, then press ENTER:
InhibitDisar ---
None
14.Using Aor B,select a Timer to filter the Disarm com-
mands, then press ENTER.