n Connecting Readers
Readers can be located in places where limited control
of the system is required (Arming, A and B Mode
Arming, Disarming and Stop Alarm operations).
This system supports Digital Key and Proximity Card
Readers.
Key Readers Key Readers can be flush mounted to
most standard domestic light-switch/plug-socket outlet
boxes
(refer
to
"Accessory
"INTRODUCTION" for the available models).
+
Digital Key Readers must be at least 10 cm apart.
To install Key Readers, work carefully through the fol-
lowing steps (see Figure on page 13).
1. Assign the Reader Address, then set the BPI Level
and complete the connections on the terminal
board (refer to "Connecting BPI Peripherals" for in-
structions).
2. Fit the Reader in its placement (use the standard
procedure for fitting domestic light-switches and
plug sockets).
Proximity Readers Proximity Readers can be surface
mounted, or mounted to Mod. 503 outlet boxes or simi-
lar. Proximity Readers are fitted with weather strips
(Protection Class IP34), therefore, are suitable for out-
door use.
+
Proximity Readers must be at least 50 cm apart.
To install Proximity Readers, work carefully through the
following steps (see Figure on page 13).
3. Remove the screw 90 (if fitted), then using a screw -
driver or similar tool push down on the catch 93 to
release the frontplate.
Figure 10 Mounting Key Readers
16
items"
in
the
to the
Tamper line
4. Drill the holes for the backplate and Seize
microswitch bracket anchor screws (83 and 88 re -
spectively).
5. If you are fitting a Seize microswitch (Order Code:
ASNC-MINI), push it firmly into its location (87 in
Fig. 7) then connect it to the connector 86. Ensure
that the Seize microswitch lever is held firmly in po -
sition by the bracket tooth.
6. Secure the Reader and Seize microswitch bracket
to the wall.
7. Assign the Reader Address, set the BPI Level and
complete the connections on the terminal board
(refer to "Connecting BPI Peripherals" for instruc -
tions).
8. Reattach the frontplate.
n Connecting Input and Output Expanders
Locate the Input and Output Expanders as near as pos -
sible to the devices they will be connected to.
The Expander box can be surface or flush mounted
(see Figure on page 14).
1. Remove the knockout (106 or 108 as required).
2. – Surface mounting: drill the holes for the backplate
and Seize microswitch bracket anchor screws (109
and 110 respectively).
– Flush mounting to Mod. 503 outlet box or similar:
drill the hole for the Seize microswitch bracket an -
chor screw 107. No other drilling is required for
Flush mounting.
3. Pull the wires through the wire entry.
4. Secure the back box and Seize microswitch
bracket to the wall.
+
The Seize microswitch bracket 110 must be fitted
as shown in the figure on page 14 (with the plastic
tooth to the left of its location).
5. Replace the PCB inside the box.
6. Assign the Address, then set the BPI Level and com-
plete the connections on the terminal board 72 (refer to
"Connecting BPI Peripherals" for instructions).
7. Remove the Jumper 100 — to enable the Tamper
and Seize microswitches.
8. Using the Jumper 99, set the Output Expander
buzzer mode:
1 ooo 3 > buzzer disabled (at default);
1 //o 3 > buzzer will sound when terminal [OC6]
opens;
1 o// 3 > buzzer will sound when terminal [OC6]
closes to negative.