Connecting The Receiver; Technical Specifications - Bentel Security KYO 320 Installation Manual

Expandable multifunction control panel
Hide thumbs Also See for KYO 320:
Table of Contents

Advertisement

6. Place the backplate in the proposed placement, pull
the wires through the wire entry 125, then secure
the backplate to the wall (use anchor screws).
7. Complete the connections on the terminal board
127 (refer to "Connecting the Receiver").
8. Push the frontplate spring catches into the slots on
the backplate then push the bottom of the frontplate
into place.
9. Fasten the screws 124.
n Connecting the Receiver
Connect the Receiver terminal 127 to the Control panel
terminal (as shown in Figure 9).
+
Use Shielded cable for the connection: connect
one end of the shield to terminal BLK on the Inter-
face, and leave the other end free. Do not use more
than 50 metres total wire length.
n Technical Specifications
The following table contains the technical Specifica-
tions of the Vector Receivers.
Voltage
Current draw
VectorRX-8 and
VRX32-433 Frequency
VRX32-433 Frequency
Dimensions (W x H x D)
VectorRX-8 Dimensions
VRX32-433 and 868
Dimensions
VRX32-433 and
VRX32-868 Weight
VectorRX-8 Weight
Figure 9 Connecting the receivers to the Control panel
44
13.8 V_
50 mA
433 MHz
868 MHz
146 x 290 x 28 mm
135 x 79 x 26
145 x 105 x 25
152 g
90 g
RED
BLK
YEL
GRN
YEL2
RED
133
138
145
144
144
141
140
139
Figure 10 K-NET components
Control Panel
BLK
YEL
GRN
BLK
RED
Receiver 1
Receiver 2
134
130 131 129
132
+V M OC
PC-LINK
S
L
YEL
GRN
135
136
137
138
142
143
KYO320

Advertisement

Table of Contents
loading