5h. Enter the keypad message for the Installer Mainte-
nance Request memo (refer to "Entering a text" under
"Using the Keypad"), then press E to go back to step 3.
n Central Station call
Cent.Stat.Date
Disabled
4i. Enter the time and date for the Central station call
memo (enter all zeros to disable this option), then press
ENTER.
Description
Cent.Stat.call
5i. Enter the keypad message for the Central Station Main-
tenance call memo (refer to "Entering a text" under "Using
the Keypad"), then press ENTER to go back to step 3.

Options

1. Using A or B, select Options from the
PROGRAMMING menu:
PROGRAMMING
Options
2. Press ENTER:
Mains fault tim.
Min.
0003
3. Enter the time (in minutes) the Control panel must
wait before signalling blackout (Mains fault timeout),
then press ENTER.
+
For the system to conform to EN50131, this value
must not exceed 60 minutes.
Max.Wrong
PINs
Number
03
4. Enter the number of times the keypad will allow entry
of wrong PINs before locking or enter 0 (zero) to disable
this option, then press ENTER.
Lock
Time
Min.
03
5. Enter the amount of time (in minutes) the keypad
must lock for, then press ENTER.
Option section 1
No us.res.tamp.-
6. Using A or B, select the required option (see Table
9), then press ON or OFF, respectively, to enable or di-
sable the option concerned. Press ENTER to go to the
next Option section 2.
KYO320
Option section 2
Block ist.code -
7. Using A or B, select the required option (see Table
9), then press ON or OFF, respectively, to enable or di-
sable the option concerned. Press ENTER to go to the
next Option section 3.
Option section 3
Realtime Chime
8. Using A or B, select the required option (see Table
9), then press ON or OFF, respectively, to enable or di-
sable the option concerned. Press ENTER to continue.
+
NOTE: At this step, if you have already enabled the
Continuous Recording option (Option section 1),
the 'Stop Recording Events' will be shown
Option section 1
Cont.Recording
Stop recording01
Event n.
9. This programming field will allow you to program the
Events (up to 32) which will interrupt Continuous Re-
cording. Using A or B, select a position, then enter the
event ID number (refer to the Event Tables ). The event
ID numbers must be entered without zeros, for exam-
ple, for event 0001, enter 1. Enter 0 to deselect all
events. Press ENTER to continue.
Timeout cont.rec
(Max 021)
10. Enter the (in seconds) between the start of an event
(from those selected) and the termination of recording.
Press E to go back to the PROGRAMMING menu.
+
NOTE: The bottom line of the display will show the
maximum value (equal to 75% of the length of mes-
sage 64).

Scheduler opt.

This programming section will allow you to program the
parameters of the Max. overtime requests and Overti-
me request options.
1. From the PROGRAMMING menu, using A or B, se-
lect Scheduler opt.:
PROGRAMMING
Scheduler opt.
2. Press ENTER:
Overtime length