n Associated Timer
If a Code is associated with a Timer, it will function only
during the programmed Timer slots (refer to "Scheduler
- Timers").
n User menu access
This section of the User page will allow you to limit the
number of operations a code can perform (Arm, Arm
Type A, B, c or D, Disarm and Access User Menu).
Always If this option is enabled, the Code will be able
to perform an UNLIMITED number of operations.
If this option is disabled, you will be able to LIMIT the
number of operations the Code will be able to perform
via the Max. option.
+
ONLY Codes with Always status can be Father
codes.
You CANNOT disable the Always status of Fa-
ther codes.
A Code that DOES NOT HAVE Always status
(Always option disabled) can be its own Father
code, in which case, the Always attribute will be
enabled automatically.
Max. This field will allow you to program the number
operations the Code will be allowed to perform.
Valid entries: 1 through 254
The Code operation counter will count all the Arm, Arm
Type A, B, c or D, Disarm and Access User Menu oper-
ations.
Once the Code reaches the Max. number of operations
allowed, it will be automatically disabled. If an attempt is
made to use a Code that has reached the Max. number
of operations (therefore disabled), the display will show
the [code not active] message.
You must change the Code PIN, if you wish to refresh
the Code operation counter.
+
ALL the Code operation counters will be refreshed
automatically each time the User page is down -
loaded.
Figure 49 Users — Code access page
78
n Father PIN
A Code's Available status, Active status, Father
codes and PIN cannot be changed without entering one
of its programmed Father codes.
+
The Code PIN at default is 0 followed by the Code
ID Number. Example: PIN of Code No. 001 is 0001.
n New PIN
This programming field will allow you to change the de-
fault PIN, as follows:
Ø enter the Code's Father Code (to activate the New
PIN programming field);
Ø enter the New digits in the New PIN and Redigit
New PIN fields, then click OK.
The digits will be masked by asterisks (*). A PIN can
have 4, 5 or 6 digits.
WARNING: The default PINs of all Available Codes
must be changed for security reasons.
+
You cannot change a Code's Father code/s with -
out first entering the PIN of one of its Father codes.
Redigit New PIN Enter the digits of the New PIN in
this field.
If the entry is correct (both fields match), the PIN fields
will clear when you click OK, and the New PIN will be -
come Valid.
In the event of mismatch, the PIN fields will not clear,
and it will be necessary to repeat the procedure.
n Code Type
This parameter determines the Code functions — pro -
grammed in the Code Types page (refer to "Keypad
codes - Codes types").
n Enable on LCD Keypad
The "Enable LCD keypad" table will allow you enable
the code concerned on the LCD Keypads (32 keypads
for KYO320).