TORQUE
Camshaft Carrier Bolts:
7 ft-lb (10 Nm)
13. Measure and confirm that valve clearance is now
within specification for each valve.
14. If valve clearance is not within specification, repeat
this procedure.
15. If all valve clearance measurements are now within
specification, remove the camshaft carriers and
proceed to Camshaft Installation / Timing, page
2.32

CAM CHAIN TENSIONER INSPECTION

1. Locate the cam chain tensioner on the MAG side of
the engine near the starter.
2. Remove the plunger bolt
3. Remove the two tensioner mounting bolts
4. Push on the tensioner lock
plunger in and out. It should move freely. If it does not
move freely, replace the tensioner assembly.
5. Retract the plunger all the way in and install into the
cylinder.
6. Install the two mounting bolts. Torque fasteners to
specification.