Pilot Shutoff Lever

The pilot shutoff lever (1) shuts off hydraulic pilot pressure
to all pilot control valves. When pilot shutoff lever is in
locked (UP) position, the machine will not move if a lever
or pedal is accidentally moved. Engine will not start with
pilot shutoff lever in the unlocked (DOWN) position.
Always pull pilot shutoff lever to locked (UP) position when
stopping the engine or leaving operator's station.
Push pilot shutoff lever forward to unlocked (DOWN)
position to operate machine.
1— Pilot Shutoff Lever

Left Console

NOTE: There are standard and optional switches on
the left console. Before using the switches on the
left console, be aware of what kind of optional
devices are equipped on the machine.
Raise the armrest when operating the switches.
1— Reversing Fan Switch (if
equipped)
2— Seat Heater Switch (if
equipped)

Travel Alarm and Travel Alarm Cancel Switch

NOTE: If alarm is not operating during normal transport or
if alarm sounds when engine is running and machine
is stationary, see an authorized John Deere dealer.
The travel alarm sounds when a travel pedal or lever
is activated and will continue as long as the tracks are
moving. When travel motion stops, the travel alarm switch
is reset.
After the initial 13-second alarm, alarm can be silenced by
depressing the right half of the travel alarm cancel switch
(1) located on the left console.
1— Travel Alarm Cancel Switch
Operation—Operator's Station
3— Travel Alarm Cancel Switch
2-1-5
Lever in Locked (UP) Position
OUT4001,000073E -19-12JUN15-1/1
Left Console
OUT4001,000073F -19-09OCT17-1/1
Travel Alarm Cancel Switch
OUT4001,0000740 -19-19FEB18-1/1
092221