Drain Auxiliary Fuel Filter and Water
Separator—If Equipped
1. Open right service door to access auxiliary fuel filter
and water separator (1).
NOTE: Drain waste into a container. Dispose
of waste properly.
2. Open drain valve (3) on bottom of water separator
bowl (2) to extract water from fuel system. Drain until
water and sediment is removed. Collect waste in a
container and dispose of waste properly.
3. Close drain valve.
1— Auxiliary Fuel Filter and
Water Separator
2— Water Separator Bowl
Lubricate Working Tool Pivots
Lubricate working tool pivots (4 points) until grease
escapes from joints. Lubricate every 4 hours for first 20
hours. Lubricate every 10 hours during first 30—100
hours and when working in mud and water.
Maintenance—Every 50 Hours or Weekly
3— Drain Valve
3-5-2
Auxiliary Fuel Filter and Water Separator
DB84312,00000E5 -19-27JAN12-1/1
Four Points
VD76477,000036F -19-27MAY11-1/1
092221