Main Menu—Information
Menu—Maintenance
The Maintenance menu provides the capability to notify
the operator when the next maintenance item is due,
shows hours remaining until next maintenance interval,
and allows the interval hours to be reset.
At Information Menu, rotate monitor dial to highlight
Maintenance. Press monitor dial to display Maintenance
menu.
Maintenance menu items include:
Engine Oil
Engine Oil Filter
Hydraulic Oil
Pilot Hydraulic Oil Filter
Hydraulic Oil Full-Flow Filter
Pump Transmission Oil
Travel Reduction Gear Oil
Swing Reduction Gear Oil
Swing Bearing Grease
Air Cleaner Element
Fuel Filter
Air Conditioner Filter
Exhaust Filter
User Setting 1
User Setting 2
Maintenance Notice...........ON or OFF
Rotate monitor dial to highlight Maintenance Notice.
Press monitor dial to turn Maintenance Notice ON. Press
monitor dial again to turn Maintenance Notice OFF.
If Maintenance Notice is ON, a message is displayed on
the monitor for 10 seconds (when the key switch is in ON
Main Menu—Information
Menu—Troubleshooting
The Troubleshooting menu provides access to view any
diagnostic trouble codes (DTCs) generated by a controller.
At Information Menu, rotate monitor dial to highlight
Troubleshooting. Press monitor dial to begin
Troubleshooting data. After displaying Wait message, the
screen displays controller troubleshooting menu:
Engine (00)
Main (00)
Operation—Monitor Operation
position) if any of the maintenance items listed come due
for a change. Press the Home button on switch panel to
delete the notification.
If Maintenance Notice is OFF, no notification is displayed
on the monitor.
To check if a maintenance item is due for a change,
rotate monitor dial through list to reach specific item and
highlight. If a wrench symbol appears next to the item,
service is due. Press monitor dial to display the following
information for each item:
Previous Maintenance
(date is displayed).............X.X h
Remains...........................XXX.X h
Maintenance Interval......XXX.X h
Press monitor dial to return to previous menu with no
changes.
To reset remaining time data, rotate monitor dial to
highlight RESET at the bottom center of monitor and
press monitor dial. The value of remaining hours is reset
to that of change interval. The previous maintenance date
and hours are updated with current date and time.
To change the maintenance interval, rotate monitor
dial to highlight the wrench with the clock next to it at the
bottom right corner of monitor and press monitor dial.
(Backlighting will turn orange for Maintenance Interval.)
Rotate monitor dial to adjust the time for scheduled hour
maintenance. Press monitor dial to store the change.
Press back button to return to previous screen.
Press home button to return to default screen.
Monitor (00)
Information (00)
Option (00)
The amount of currently generated DTCs is displayed at
the right side of each item in parentheses. Rotate monitor
dial to highlight an item displaying DTCs. Press monitor
dial to display the actual DTC numbers. Up to 20 DTCs
can be displayed.
Press back button to return to previous screen.
Press home button to return to default screen.