Travel Alarm Cancel
Switch Circuit Check
TX1086700A —UN—08JAN11
1— Reversing Fan Switch—If Equipped
2— Seat Heater Switch—If Equipped
3— Travel Alarm Cancel Switch
NOTE: Travel alarm must operate for this check.
Place pilot shutoff lever in unlocked (DOWN) position.
Push travel pedals or levers and allow travel alarm to operate for a minimum of 12
seconds.
LISTEN: Does travel alarm sound?
While continuing travel, press travel alarm cancel switch (1).
LISTEN: Does travel alarm stop sounding?
Miscellaneous—Operational Checkout
CAUTION: Avoid possible injury. Machine will move during this check.
Make sure area is clear and large enough to operate machine.
4-2-22
Left Console
Continued on next page
YES: Go to next check.
NO: See your authorized
dealer.
CN93077,000003A -19-16MAY13-28/53
092221
PN=227