Monthly Storage Procedure - Worldwide Construction And Forestry Division 380GLC Operator's Manual

Table of Contents

Advertisement

Monthly Storage Procedure

CAUTION: Prevent possible injury or death
from asphyxiation. Engine exhaust fumes
can cause sickness or death. Start engine
ONLY in a well-ventilated area.
1. Drain water and sediment from fuel tank when air
temperature is above freezing.
2. Remove LPS 3® Rust Inhibitor from cylinder rods with
a cleaning solvent.
LPS 3 Rust Inhibitor is a trademark of Illinois Tool Works.
IMPORTANT: Prevent possible engine damage.
During cold temperatures, check fluidity of
engine oil on dipstick. If the oil appears waxy
and/or jelly-like rather than liquid, DO NOT
attempt to start engine. Use external heat source
to warm the crankcase until oil appears fluid.
3. Check all fluid levels. If low, check for leaks and add
oil as required.
4. Check belts.
5. Check condition of all hoses and connections.
6. Check battery electrolyte level. Charge and install
battery.
7. For machines with tires, check condition of tires and
tire pressure.
For machines with tracks, check condition of tracks
and track sag.
On crawler machines with non sealed-and-lubricated
track chains, apply oil to the pin-to-bushing joints. Run
machine back and forth several times.
8. Park machine on a hard surface to prevent tracks from
freezing to ground.
9. Fill fuel tank.
10. Pre-lubricate turbocharger bearings, if equipped:
a. Disconnect fuel shutoff fuse.
b. Crank engine for 10 seconds.
c. Connect fuel shutoff fuse.
11. Inspect engine compartment, and remove any foreign
material that may have accumulated. Start engine and
Miscellaneous—Storage
run until it reaches operating temperature. Run at 1/2
speed for 5 minutes. Do not run at fast or slow idle.
If engine does not start or runs poorly after starting,
change fuel filters. Bleed fuel system.
12. Operate all controls, levers, seat adjustments, etc.
CAUTION: Prevent possible injury from
unexpected machine movement. Clear the
area of all persons before running machine
through the operation procedure.
13. Make sure the area is clear to allow for movement.
Cycle all hydraulic functions several times. Check
condition of all hoses and connections.
14. Park the machine with cylinder rods retracted, if
possible. Shut engine off.
15. Apply LPS 3 Rust Inhibitor to exposed cylinder rod
areas.
4-4-2
Clean Cylinder Rods
VD76477,0000003 -19-04JAN13-1/2
Check Oil on Dipstick
VD76477,0000003 -19-04JAN13-2/2
092221
PN=261