Worldwide Construction And Forestry Division 380GLC Operator's Manual page 219

Table of Contents

Advertisement

Monitor and Gauge
Circuit Checks
TX1087196A —UN—28JUN13
1— Power Mode Indicator
2— Hour Meter
3— Engine Coolant Temperature Gauge
4— Fuel Gauge
5— Alarm Indicator
IMPORTANT: Engine damage could occur if the alarm indicator (5)
NOTE: The exhaust filter auto cleaning disabled indicator will display on the
Start engine.
LOOK: Do all alarm indicator displays remain off after engine starts?
LOOK: Does alarm indicator remain off after engine starts?
LOOK: Does engine coolant temperature gauge (3) display correct engine coolant
temperature?
LOOK: Does fuel gauge (4) display correct fuel level?
Miscellaneous—Operational Checkout
Operating Screen
or engine oil pressure alarm indicator comes on after engine
starts. Turn off machine immediately.
monitor when the key switch is in ON position. Once the engine is
started, the indicator will disappear unless exhaust filter auto cleaning
has been disabled by the operator through the monitor.
4-2-14
Continued on next page
YES: Go to next check.
NO: Engine oil pressure
alarm displayed.
Immediately stop engine
and check engine oil level.
See Check Engine Oil
Level. (Section 3-4.)
IF OK: See your authorized
dealer.
NO: Alternator alarm
indicator displayed. Check
alternator drive belt.
IF OK: See your authorized
dealer.
NO: See your authorized
dealer.
CN93077,000003A -19-16MAY13-20/53
092221
PN=219