Main Menu—Information Menu—Monitoring
The Monitoring menu provides access to view engine
speed and restriction level in the exhaust filter.
At Information Menu, rotate monitor dial to highlight
Monitoring. Press monitor dial to display Monitoring menu:
Actual Engine Speed...........XXXX min-¹
Exhaust Filter Restriction Level....(displays a bar
graph)
There are five segments to the bar graph to indicate the
restriction status of the exhaust filter.
Operation—Monitor Operation
- If any of the first three segments of the bar graph
display a block, auto cleaning needs to be enabled.
- If the fourth or fifth segment also displays a block, a
parked cleaning needs to be initiated by the operator.
An exhaust filter alarm indicator will also appear on
the monitor.
Press back button to return to previous screen.
Press home button to return to default screen.
2-2-26
OUT4001,0000734 -19-31AUG15-1/1