Inspect Serpentine Belt; Drain And Refill Pump Drive Gear Case Oil - Worldwide Construction And Forestry Division 380GLC Operator's Manual

Table of Contents

Advertisement

Inspect Serpentine Belt

1. Check belt (1) regularly for wear, especially for cracks
at the bottom of grooves and for frayed edges.
2. If necessary, replace belt.
3. Install a 1/2 in. drive socket wrench to the belt tension
adjuster (2). Turn wrench to pull tension adjuster
pulley away from belt, releasing belt tension.
4. Hold tension adjuster away from belt while removing
old belt and installing new belt.
5. Slowly release wrench tension to allow tension
adjuster to move against new belt. Tension is
automatically adjusted.
6. Remove wrench.
1— Belt
2— Belt Tension Adjuster
3— Alternator

Drain and Refill Pump Drive Gear Case Oil

1. Open right service door to access pump drive gear
case.
2. Remove filler plug (2).
3. Remove drain plug (3). Allow oil to drain into a
container. Dispose of waste oil properly.
4. Apply liquid pipe thread sealant to drain plug. Install
plug.
Specification
Pump Drive Gear
Case—Oil Capacity.......................................................................... 1.1 L
5. Add oil. See Pump Drive Gear Case Oil. (Section 3-1.)
6. Remove dipstick (1), and check oil level. Oil level must
be approximately halfway below H mark.
7. Install filler plug.
8. Install dipstick.
9. Close right service door.
1— Dipstick
2— Filler Plug
Maintenance—Every 1000 Hours
4— Crankshaft Pulley
5— Idler Pulley
1.2 qt.
3— Drain Plug
3-9-4
Serpentine Belt
DB84312,00000EB -19-27JAN12-1/1
Pump Drive Gear Case
Pump Drive Gear Case Oil Level