Main Menu—Setting Menu—Auto-Shutdown
The Auto-Shutdown menu provides the capability to
turn on this feature and set a desired time for machine
shutdown to take place.
At Setting Menu, rotate monitor dial to highlight
Auto-Shutdown. Press monitor dial to display
Auto-Shutdown menu.
Auto-Shutdown menu items include:
NOTE: When auto-shutdown is ON, the color of the
preceding square is green and A/S will appear on
the default screen. When auto-shutdown is OFF,
the color of the preceding square is gray.
ON (Enable)
Rotate monitor dial to highlight ON (enable). Press
monitor dial to turn the auto-shutdown function ON.
Press monitor dial again to turn the auto-shutdown
function OFF.
NOTE: Setting Time minute increment needs to be
set before enabling auto-shutdown.
Operation—Monitor Operation
Setting Time
Rotate monitor dial to highlight Setting Time and
press monitor dial (backlighting turns orange). Rotate
monitor dial to adjust the auto-shutdown acting time.
Auto-shutdown can be set to activate after 1, 2, 3, 4,
5, 7, 10, 15, 20, 25, or 30 minute increments. Press
monitor dial to store desired time setting.
The following conditions must be met in order for
auto-shutdown to work:
Engine operated in auto-idle for the set amount of time
that was selected for auto-shutdown.
Pilot shutoff lever is in locked (UP) position.
Engine coolant temperature is greater than 60°C
(140°C) but lower than 100°C (212°F).
Exhaust filter cleaning is not active.
NOTE: Thirty seconds before the engine stops, the monitor
will display Engine Shutdown Soon message.
Press back button to return to previous screen.
Press home button to return to default screen.
2-2-17
KR46761,00015D5 -19-31JUL17-1/1
092221
PN=92