Replace Air Cleaner Elements; Replace Air Cleaner Dust Unloader Valve - Worldwide Construction And Forestry Division 380GLC Operator's Manual

Table of Contents

Advertisement

Replace Air Cleaner Elements

1. Open front left service door to access air cleaner.
2. Release latch (1) to unlock cover.
3. Rotate cover counterclockwise, and remove cover.
4. Remove primary element (2).
5. Remove secondary element (3).
6. Clean the inside of the filter canister.
7. Install elements, making sure the secondary element
is centered in canister.
8. Replace cover and secure latches.
9. Close rear side shield.
1— Latch
2— Primary Element

Replace Air Cleaner Dust Unloader Valve

NOTE: A missing, damaged, or hardened dust
unloader valve (1) will cause the air filter
elements to be ineffective.
1. On left side of machine, open rear side shield to
access dust unloader valve (1).
2. Twist and pull on dust unloader valve to remove dust
unloader valve from the air cleaner cover.
3. Install new dust unloader valve on air cleaner cover.
1— Dust Unloader Valve
Maintenance—Every 1000 Hours
3— Secondary Element
3-9-6
Air Cleaner Cover Latch
Primary Air Cleaner Element
Secondary Air Cleaner Element
ER79617,0000D7F -19-28JAN11-1/1
Dust Unloader Valve
ER79617,0000D7A -19-28DEC10-1/1
092221