IMPORTANT: If water is added to batteries during
freezing weather, batteries must be charged
after water is added to prevent batteries from
freezing. Charge battery using a battery
charger or by running the engine.
2. Fill each cell to within the specified range with distilled
water. DO NOT overfill.
CAUTION: Prevent possible injury. ALWAYS
remove grounded (-) battery clamp first
and replace it last.
3. Disconnect battery clamps, grounded clamp first.
4. Clean battery terminal (4) and clamps with a stiff brush.
5. Apply lubricating grease (5) around battery terminal
base only.
6. Install and tighten clamps, grounded clamp last.
1— Battery Post
2— Fill Tube
3— Electrolyte Level Range
Maintenance—Every 250 Hours
4— Battery Terminal
5— Lubricating Grease
3-7-5
Battery Terminal and Fill Hole
Fill Level
4
5
Terminal and Grease
TX,HYBATT,CHK -19-24APR20-2/2
092221
PN=164