Check Pump Drive Gear Case Oil Level
1. Open right service door to access pump drive gear
case.
2. Remove dipstick (1).
3. Wipe dipstick clean and insert completely into tube.
4. Remove dipstick.
5. Oil level must be approximately halfway below the H
mark. Insert dipstick.
To add oil:
1. Remove filler plug (2).
2. Add oil. See Pump Drive Gear Case Oil. (Section 3-1.)
3. Install filler plug.
1— Dipstick
Maintenance—Every 250 Hours
2— Filler Plug
3-7-3
Pump Drive Gear Case Oil Level
Pump Drive Gear Case Oil Level
ER79617,0000AF1 -19-14APR16-1/1