4. Press right arrow (B) to select YES. Press SELECT (C).
•
TO CALIBRATE SELECT is displayed in upper line.
5. Press left (A) or right (B) arrow until HEADER FLOAT is
displayed on the lower line. Press SELECT (C).
•
CALIBRATING FLOAT is displayed on the
upper line.
•
PRESS FLOAT + TO START is displayed on the
lower line.
CAUTION
Check to be sure all bystanders have cleared the area.
6. Press and hold FLOAT + button (A) on the CDM.
•
CALIBRATING FLOAT is displayed on the
upper line.
•
FLOAT ( + ) HOLD is displayed on the lower line.
NOTE:
The word HOLD will flash during calibration. FLOAT (+)
DONE will display on the lower line once calibration is
complete.
7. Release the FLOAT + button (A).
•
CALIBRATING FLOAT is displayed on the
upper line.
•
FLOAT ( – ) HOLD is displayed on the lower line.
8. Press and hold FLOAT – button (A) on CDM.
•
CALIBRATING FLOAT is displayed on the
upper line.
•
FLOAT ( – ) HOLD is displayed on the lower line.
NOTE:
The word HOLD will flash during calibration. HDR
FLOAT COMPLETE will display on the lower line once
calibration is complete.
9. Release FLOAT – button (A).
•
TO CALIBRATE SELECT is displayed on the
upper line.
•
HEADER FLOAT is displayed on the lower line.
10. Press right arrow to select next header sensor calibration or STOP & EXIT. Press SELECT. Refer to
Calibrating the Header Height Sensor, page 182
11. Press PROGRAM to exit Programming Mode.
214298
CAB DISPLAY MODULE (CDM)
Figure 4.88: M155 Header Float Display Shown
– M205 Similar
Figure 4.89: M155 Positive Header Float Display
Shown – M205 Similar
Figure 4.90: M155 Negative Header Float
Display Shown – M205 Similar
or
4.6.2 Calibrating the Header Tilt Sensor, page
187
4.6.1
184.
Revision A