Table 5.4 Battery and Alternator Condition
Ignition
Engine
Running
ON
Shut down
NOTE:
Display flashes voltage reading accompanied by a single loud tone every 30 minutes until condition is fixed.

5.11.6 Checking Operator's Presence System

CAUTION
Check to be sure all bystanders have cleared the area.
1. Start the engine.
2. Place the ground speed lever (GSL) (A) in NEUTRAL
and turn the steering wheel until it locks.
3. Engage header drive switch (B).
4. Stand up from the operator's seat. The header should
shut off after approximately 5 seconds. If the header
does not shut off, the Operator Presence System
requires adjustment. Refer to the technical manual.
NOTE:
To restart the header, move the header drive switch (B)
to the OFF position and then back to the ON position.
214298
PERFORMING PREDELIVERY CHECKS
Reading
13.8–15.0
>16.0 (see note)
<12.5 (see note)
12.0
231
Indicated Condition
Regulator out of adjustment
Alternator not working
Regulator out of adjustment
Battery normal
Figure 5.22: Operator Console
Normal