Figure 83. Connecting the Positive (+) Power Wire with a Straight Terminal
7. With a #3 Phillips-head screwdriver, connect the negative (-) power
lead wire to the negative terminal on the power supply, with the
remaining terminal screw removed in step 5. The negative terminal is
on the right. You may attach the terminals with the wires either above
or below the terminal block. Figure 84 on page 136 shows the wires
above the terminal block.
Allied Telesis recommends tightening the screw to 30 to 40 inch-lbs.