Advertisement

Chapter 8: Replacing Modules
192
Note
If the power wires are connected to the terminal block with the right
angle terminals, go to step 5.
4. Use a #1 screwdriver to loosen the two screws that secure the plastic
cover over the terminal block and slide the cover to the right. You may
need to slightly lift the locking handle to access the bottom screw.
Refer to Figure 113
The plastic cover might not be present if you used the right angle
terminals to connect the lead wires to the terminal block. If this is the
case, skip this step.
Figure 113. Opening the Plastic Window over the Terminal Block
5. Use a #3 screwdriver to remove the negative (-) lead wire from the
terminal block. The negative lead wire is on the right. Refer to Figure
114 on page 193.