Chapter 1: Overview
eco-friendly
Button
Reset Button
42
A cooling fan has failed.
The internal temperature of the switch has exceeded the normal
operating range and the switch may shut down.
Note
You can use the SHOW SYSTEM ENVIRONMENT command in the
command line interface to identify the source of the problem.
You use the eco-friendly button on the management panel to turn the
LEDs on or off. You can turn off the LEDs when you are not using them to
monitor the control and Ethernet line cards, to conserve electricity. When
the LEDs are off, the overall power consumption of the switch is slightly
reduced by approximately 2 watts.
The button controls all the port LEDs on the Ethernet line cards and
management panel, except for the L/A LED for the NET MGMT port. The
button does not control the LEDs on power supply systems.
Pressing the Reset button resets all the Ethernet line cards in the switch.
You might perform this function if the switch and line cards are
experiencing a problem.
Caution
The Ethernet line cards do not forward network traffic for about three
minutes while they initialize the AlliedWare Plus operating system
and configure their parameter settings. Some network traffic may be
lost.
Note
To reset individual line cards, use the REBOOT or RELOAD
command in the AlliedWare Plus operating system.