Figure 72: Connecting The Positive (+) Power Wire With A Straight Terminal - Allied Telesis SwitchBlade x908 GEN2 Installation Manual

Stand-alone switches
Hide thumbs Also See for SwitchBlade x908 GEN2:
Table of Contents

Advertisement

Figure 72. Connecting the Positive (+) Power Wire with a Straight Terminal
7. With a #3 Phillips-head screwdriver, connect the negative (-) power
lead wire to the negative terminal on the power supply, with the
remaining terminal screw removed in step 5. The negative terminal is
on the right. You may attach the terminals with the wires either above
or below the terminal block. Figure 73 on page 108 shows the wires
above the terminal block.
Allied Telesis recommends tightening the screw to 30 to 40 inch-lbs.
SBx908 GEN2 Installation Guide for Stand-alone Switches
107

Advertisement

Table of Contents
loading

Table of Contents