Introduction to Attaching the Power Wires

The SBxPWRSYS1-80 DC Power Supply comes with the two sets of
power wire terminals, shown in Figure 78. You may use either set to
connect the positive (+) and negative (-) wires to the terminal block on the
power supply. The straight terminals are used to route the wires above or
below the terminal block. The right angle terminals are used to route the
power wires directly away from the terminal block.
Straight Terminals
Figure 78. Power Wire Terminals
Note
The right angle terminals require the removal of the plastic cover
from the terminal block.
You can also install the wires using bare wires.
Here are the procedures for wiring the positive and negative terminal block
on the power supply:

"Connecting the DC Power Wires with the Straight Terminals" on

page 132
"Connecting the DC Power Wires with the Right Angle Terminals" on
page 139
"Connecting Bare DC Power Wires" on page 145
SBx908 GEN2 Installation Guide for Virtual Chassis Stacking
Right Angle Terminals