Connecting The Dc Power Wires With The Right Angle Terminals; Figure 87: Attaching The Power Wires To The Right Angle Terminal Lugs - Allied Telesis SwitchBlade x908 GEN2 Installation Manual

Advanced layer 3+ modular switch alliedware plus v5.4.9-2, virtual chassis stacking
Hide thumbs Also See for SwitchBlade x908 GEN2:
Table of Contents

Advertisement

Connecting the DC Power Wires with the Right Angle Terminals

To use the right angle terminals to connect the DC power wires to the
positive and negative terminals on the SBxPWRSYS1-80 DC Power
Supply, perform the following procedure:
1. Prepare adequate lengths of two stranded 8 AWG power wires by
stripping them as shown in Figure 79 on page 132.
Warning
Do not strip more than the recommended amount of wire. Stripping
more than the recommended amount can create a safety hazard by
leaving exposed wire on the terminal block after installation.  E10
Note
You must use stranded wires with the terminal lugs. You may not
use solid wires.
2. Insert the power wires into the terminals included with the power
supply and use a crimping tool to secure the wires to the terminals.
See Figure 87.
Figure 87. Attaching the Power Wires to the Right Angle Terminal Lugs
3. Verify that the On/Off switch on SBxPWRSYS1-80 DC Power Supply
is in the Off position. Refer to Figure 71 on page 124.
4. Using a #1 Phillips-head screwdriver, remove the two screws that
secure the plastic cover over the positive and negative terminals and
remove the plastic cover from the power supply, as shown in Figure 88
on page 140. You may need to lift the locking handle slightly to access
the bottom screw.