Unable To Boot The Mivoice Business System On 3300 Icp Controller - Mitel MiVoice Business 3300 ICP Troubleshooting Manual

Table of Contents

Advertisement

Software
Software on a 3300 ICP Controller (Manually) in the MiVoice Business Technician's
Handbook.
If any of the parameters needs to be modified, modify their values as follows:
a.
Run the following command to modify the U-Boot configuration file values.
run ubootcfg
b.
Update the relevant parameter as needed.
10.
Without resetting the system, run the following command to save the updated U-Boot
variables from RAM to FLASH.
saveenv
Now you should be able to initiate the full manual full installation of your ICP3300
Controller.
4.3 Unable to boot the MiVoice Business System on 3300 ICP
Controller
Overview
You must
Recover the system through the Server Manager
the MiVoice Business software is unable to boot from the HDD (or SSD) of your 3300
ICP Controller.
the MiVoice Business application fails to boot several times. In this case, the error
message Detected several incomplete MiVoice Application reboots.
The MiVoice Business services are currently disabled. A manual
reboot is required after the root cause is addressed is displayed.
Recover the system through the Server Manager
Recover the System through SSH
Recover the System through the Maintenance Port
Password Recovery for 3300 ICP Controller
Unable to Recover the MiVoice Business System from Active and Inactive Partitions
on page 123
117
on page 118
on page 118
on page 119
on page 121