Fujitsu AIRSTAGE J-IIIL Design & Technical Manual page 490

Table of Contents

Advertisement

 BACnet object list
• Type: Indoor
BACnet
object
Code (II)
type
10
Set temp. status
11
Space temp.
12
Auto temp. (Low limit status)
13
Auto temp. (High limit status)
AI
14
Cool/Dry temp. (Low limit status)
15
Cool/Dry temp. (High limit status)
16
Heat temp. (Low limit status)
17
Heat temp. (High limit status)
10
Temp. setting
11
Auto temp. (Low limit setting)
12
Auto temp. (High limit setting s)
AO
13
Cool/Dry temp. (Low limit setting)
14
Cool/Dry temp. (High limit setting)
15
Heat temp. (Low limit setting)
16
Heat temp. (High limit setting)
AV
10
ECA* operation data
10
Operation status
14
Filter sign status
15
Indoor unit error status
16
Anti-freeze operation status
17
SAVE operation status
BI
18
Forced thermostat off status
19
Emergency stop status
20
Mode mismatch status
21
Protect anti-freeze status
22
Temp. limit valid status
10
Operation setting
14
Filter sign resetting
15
Anti-freeze operation setting
BO
16
SAVE operation setting
17
Forced thermostat OFF setting
18
Emergency stop setting
19
Temp. limit valid setting
10
Operation mode status
11
Fan speed status
12
Indoor unit error code
13
R.C. prohibition status
MI
14
Vertical airflow direction status
15
Horizontal airflow direction status
16
Special driving status
17
Managed mode
10
Operation mode status
11
Fan speed setting
MO
12
R.C. prohibition setting
13
Vertical airflow direction setting
14
Horizontal airflow direction setting
TL
10
ECA* operation data log
*: Electricity charge apportionment
• Type: Outdoor
BACnet
object
Code (II)
type
30
Outdoor unit error status
BI
31
Forced off status
BO
10
Forced off setting
30
Outdoor unit priority operation status*
31
Outdoor error code
MI
32
Capacity save status
33
Outdoor low noise operation status*
30
Outdoor low noise operation status*
MO
32
Capacity save setting
*1: Priority operation status is for Heat pump type VRF. In other types of systems, this status is not necessary.
*2: Refer to the "Outdoor unit low nose operation value table" for the texts used with the "Outdoor low noise operation status".
*3: Outdoor unit firmware may need to be updated for this function to work. For details, contact your local sales company.
3-7. BACnet gateway (Software: UTY-ABGXZ1)
Function name
Inactive
Text-1
°F
°F
°F
°F
°F
°F
°F
°F
°F
°F
°F
°F
°F
°F
°F
OFF
Unsigned
Normal
Reset
Normal
Reset
Normal
Normal
Reset
Invalid
OFF
Reset
Reset
Reset
Reset
Reset
Invalid
COOL
LOW
1
1
Normal
None
COOL
LOW
1
1
Function name
Inactive
Text-1
Normal
Reset
Reset
1
COOL
Not set
2
3
Stop
Not set
- (05-152) -
Unit
Active
Text-2
Text-3
Text-4
ON
Signed
Fault
Set
SAVE
Set
Stop
Mismatch
Set
Valid
ON
Not reset
Set
Set
Set
Set
Valid
HEAT
FAN
DRY
HIGH
MED
AUTO
Refer to FGL original error code
Refer to R.C. prohibition setting chart
2
3
4
2
3
4
Defrost
Oil recovery
Master
Slave
External
HEAT
FAN
DRY
HIGH
MED
AUTO
Refer to R.C. prohibition setting chart
2
3
4
2
3
4
Unit
Active
Text-2
Text-3
Text-4
Fault
Set
Set
HEAT
Neautral
None
Refer to FGL original error code
100%
90%
80%
Level-1
Level-1
Level-2
Quiet
Ability
Quiet
100%
90%
80%
Text-5
Text-6
AUTO
QUIET
MED-LOW
MED-HIGH
SWING
5
SWING
AUTO
QUIET
MED-LOW
MED-HIGH
SWING
5
SWING
Text-5
Text-6
Text-7
70%
60%
50%
Level-2
Level-3
Level-3
Ability
Quiet
Ability
70%
60%
50%
3. Adaptor/Convertor units
Text-7
Text-8
45%
45%