• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 80 °FDB/67 °FWB (26.7 °CDB/19.4 °CWB), and outdoor temperature of 95 °FDB/75 °FWB (35 °CDB/23.9 °CWB).
– Heating: Indoor temperature of 70 °FDB/60 °FWB (21.1 °CDB/15.6 °CWB), and outdoor temperature of 47 °FDB/43 °FWB (8.3 °CDB/6.1 °CWB).
– Pipe length: 25 ft (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)
• Protective function might work when using it outside the operation range.
• *: Sound pressure level:
–
Measured values in manufacturer's anechoic chamber.
–
Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
2-11. Wall mounted type
Cooling
Heating
HIGH
MED—HIGH
MED
CFM (m
MED—LOW
LOW
QUIET
HIGH
MED—HIGH
MED
MED—LOW
LOW
QUIET
Length
Fin pitch
Rows × Stages
Face area
Pipe type (Material)
Type (Material)
Fin
Surface treatment
Type
Net material
Material
Color
Net
Gross
Net
Gross
Liquid (Flare)
Gas (Flare)
Drain hose
ASUA4TLAV1
Btu/h
4,000
kW
1.2
Btu/h
4,400
kW
1.3
W
13
253 (430)
247 (420)
230 (390)
3
/h)
224 (380)
212 (360)
194 (330)
W
31
30
28
dB (A)
26
24
22
in (mm)
FPI
2
2
ft
(m
)
Approximate color of Munsell N9.25/
10-5/16 × 32-5/16 × 8-1/8 (262 × 820 × 206)
in (mm)
10-3/8 × 34-1/4 × 12-15/16 (263 × 870 × 328)
lb (kg)
in (mm)
I.D.: Ø 9/16 (13.8); O.D.: Ø 5/8 to 11/16 (15.8 to 16.7)