Identification / Approval; Power Supply - Dräger Cicero EM Instructions For Use Manual

Integrated anaesthetic workstation
Table of Contents

Advertisement

Technical data
Technical data
Where tolerances are given in percent and as absolute values, the higher value applies in each case!
Identification .............................: The serial number and article number of the Cicero EM and the
Dimensions...............................: See dimensional drawing on page 150.
Classification ............................: Class IIb conforming to Directive 93/42/EEC for medical devices, Appendix IX.
UMDNS code ...........................: 10 - 134 (Medical Device Nomenclature)
Weight .....................................: Standalone version approx. 190 kg. Max. 260 kg in maximum configuration.

Power supply

Operating voltages ...................: Settable on the power adapter:
Power consumption .................: Max. 370 W without auxiliary sockets and without accessories
Fuses ......................................: 2 x T7A UL 230/240 V
Auxiliary mains sockets .............: Do not connect HF surgery devices to the auxiliary power sockets, because
152
located on the rating plate (nameplate) fixed to the back of the machine
(ref. No. 17 on page 146).
Ceiling version approx. 180 kg.
If the device is equipped with a UPS (uninterruptible power supply, i.e. Cicero
Power-Pack), the power consumption of the auxiliary mains sockets is limited to
300 W.
AC
In the power adapter: 2 x 0,25 A DIN 41 662, 230/240 V
Additional fuses in power packand master switch-on contactor are only
accessible to qualified personnel with tools!
Two fuses in each auxiliary mains socket (2 A DIN 41 622, 230/240 V
Desuflorane Vapor: DIN 41662 T2A.
high interference peaks may adversely affect the operation of the Cicero EM!
(Not fitted to ceiling version)
Do not connect any additional multiple socket-outlets or socket strips to
the auxiliary mains sockets. The connection of devices to the auxiliary sockets
increases the leakage current. The risk of shock due to the overall leakage
current cannot be excluded, in particular in the event of a grounding failure in
the mains power connection to the Cicero EM.
Connecting devices to the auxiliary power sockets may increase the risk of
electric shock in the event of grounding failure!
Not switched by master power switch.
Voltage is supplied to these sockets even
when the Cicero EM is switched off but
still connected to the mains.
100 V
+10 %, -15%
AC
±10 %,
120 V
AC
±10 %,
127 V
AC
±10 %,
230 V
AC
±10 %,
240 V
AC
and 2 x M15 A UL 100/127 V
Mains socket for desflurane Vapor.
connected via master switch.
230 V
specific mains supply voltage.
C
–symbol are
50 / 60 Hz.
50 / 60 Hz.
50 / 60 Hz.
50 / 60 Hz.
50 / 60 Hz.
AC
.
AC
).
AC
: independent of the country-
AC