ECG / Heart rate

ECG display

Insert the electrode cable in the ECG input of the
parameter box, and attach the electrodes to the
patient (for instructions, see »Descriptions« from
page 163 onwards).
1 The ECG of the preprogrammed lead appears on the
system screen as specified in the configuration menu.
2 The heart rate is displayed.

Adjusting settings

Press the softkey »Parameter«. The menu
for setting the parameters is displayed.
Move the cursor frame to »ECG« with the
rotary control and press to confirm.
measuring
function
on / off
Activates and deactivates the ECG
measuring function.
number
of leads
3 / 5
Selects the type of cable used. If you are
using a 3-lead ECG cable, leads 1, 2 and 3
are available. If only 3 electrodes of a 4 or
5-lead cable are connected, the system
displays the following error message:
»Elektrode«.
lead
/
/
/ AVR / AVL / AVF / V
I
II
I I I
Selects the lead separately for the 1st, 2nd
and 3rd ECG. With a 3-core cable, the
choice is restricted to lead 1, 2 and 3.
amplitude
mV / 4 / 2 / 1 / 0.5 / 0.25
Sets the ECG amplitude in mV on the
screen in relation to the reference bar to the
left of the ECG graph. Changes to settings
are immediately visible on the curve.
filter
on / off
»on« yields an extremely stable ECG
without interference.
»off« yields an ECG with higher band
width, but less stable.
pacemaker on / off
Activates and deactivates pacemaker
pulse detection. Pacemaker pulses are
enlarged disproportionately when this
function is activated (not taken into account
when calculating the heart rate).
g
Start
AUTO
Stop
Warning:
Man./Spont. alarm limits
standard screen 1- adults
II
1
1mV
iBP1
160
0
CO
40
2
30
0
PAW
20
0
MV
L/min
O
N
O
ISO
2
2
6.0
29 70 0.8
Fi
26 68 0.6
Fet
freq 10
V
0.60
T
06-12-98
11:59
00:00
Warning:
IPPV alarm limits
standard screen 1- adults
2. ECG
II
1mV
iBP1
160
0
CO
40
2
30
0
PAW
20
0
MV
L/min
O
N
O
ISO
2
2
6.0
29 70 0.8
Fi
26 68 0.6
Fet
freq 10
V
0.60
T
06-12-98
11:59
Select the required parameter and confirm !
00:00
Warning:
IPPV alarm limits
standard screen 1- adults
2. ECG
II
1mV
iBP1 160
0
CO
40
2
30
0
PAW
20
0
MV
L/min
O
N
O
ISO
2
2
6.0
29 70 0.8
Fi
26 68 0.6
Fet
freq 10
V
0.60
T
06-12-98
11:59
Select a menu position. Please confirm !
Change the settings. Please confirm again !
00:00
Parameter box
ECG / Heart rate
d
Act.
0
0
Punct.
Advisory:
Caution:
2
HR/Pulse
ECG
ª
65
1/min
auto set
pulse def. 4
ST + 0.05
pat. alarm.
IBP1
ART
mmHg
122 / 89
pulse 65
(100)
etCO
mmHg
2
33
Peak
PEEP
32
3
plat 26
mean 21
°C
SpO
%
T
T
2
1
2
99
36.8
37.2
pulse 65
Caution:
Advisory:
HR/Pulse
ECG
ª
65
1/min
ECG
auto set
pat. alarm.
pulse def. 4
ST + 0.05
NiBP
IBP1
ART
mmHg
122 / 89
iBP 1
iBP 2
pulse 65
(100)
etCO
mmHg
2
SpO
/ Pleth
2
33
CO
/ O
2
2
pEEG
Peak
PEEP
32
3
plat 26
mean 21
°C
SpO
%
T
T
2
1
2
99
36.8
37.2
pulse 65
Caution:
Advisory:
HR/Pulse
ECG
ª
65
1/min
ECG
auto set
function
on
off
pulse def. 4
ST + 0.05
pat. alarm.
number
IBP1
ART
mmHg
3
5
of leads
122 / 89
1.ECG 2.ECG 3.ECG
lead
I
II
III
pulse 65
(100)
amplitude
1
etCO
mmHg
2
filter
33
on
off
pacemaker
on
off
pulse def.
on
off
Peak
PEEP
indication
32
3
ST-segment
analysis
on
off
plat 26
mean 21
°C
SpO
%
T
T
2
1
2
99
36.8
37.2
pulse 65
limits
auto set
vent. al.
alarm
info
screen
config.
para-
meter
timer
start
config.
limits
auto set
vent. al.
alarm
info
screen
config.
para-
meter
timer
start
config.
auto set
vent. al.
alarm
info
para-
meter
timer
start