Sign In
Upload
Manuals
Brands
Dräger Manuals
Medical Equipment
Cato
Dräger Cato Manuals
Manuals and User Guides for Dräger Cato. We have
1
Dräger Cato manual available for free PDF download: Instructions For Use Manual
Dräger Cato Instructions For Use Manual (148 pages)
Anaesthetic Workstation
Brand:
Dräger
| Category:
Medical Equipment
| Size: 2 MB
Table of Contents
Table of Contents
3
For Your Safety and that of Your Patients
4
Intended Use
5
Quick Start in an Emergency
7
Operating Concept
9
Operating Concept, General
10
Master Switch for Electricity Supply
10
Keys with Dedicated Function
11
Operating Concept of the Ventilator
11
Display Window with Dialogue Function
12
Display Window Without Dialogue Function
12
Displays
13
Keys with Dedicated Function
13
Measured Values with Grey Numerals
13
Operating Concept of the Monitor
13
Rotary Control
14
Screen Saver
14
Screen Structure
14
The Various Screen Displays
16
Preparing for Use
17
Connecting the Equipment
18
Auxiliary Electrical Equipment
18
Electricity and Gas Supply
18
Anaesthetic Agent Vaporiser
19
Anaesthetic Gas Scavenging System (AGS)
19
External Equipment
20
Uninterruptible Power Supply
20
Checking Readiness for Operation with Checklist
21
Anaesthetic Gas Scavenging
22
Vapor
22
Breathing System
23
Emergency Ventilation Bag
23
Soda Lime
23
Gas Delivery
24
Pipelinie Gas Supply
24
Reserve Gas Cylinders (Optional)
24
Water Traps
24
O 2 Flush
25
Oxygen Ratio Control (ORC)
25
Secretion Aspirator (Optional)
25
Power Supply
26
Self-Test
26
Fresh Gas - External Outlet (Optional)
27
Selecting Anaesthetic Agent
28
Automatic Calibration of O 2 /Flow Sensors
29
Manual Calibration of the O Sensor
29
Manual Calibration of the Flow Sensor
30
Ventilator Start-Up Test
31
Operation
35
Manual / Spontaneous
36
Select Manual / Spontaneous Mode
36
Spontaneous Breathing
36
Emergency Ventilation Following a Gas Failure
37
Manual Ventilation
37
Manual Ventilation Following a Power Failure
37
Fresh Gas - External Outlet (Optional)
38
Ippv
39
Selecting IPPV Mode
39
Adjusting Ventilation Parameters
39
Automatic Compliance Correction
40
Ventilation with Pressure Limitation (PCV)
40
Limit Settings
40
Selecting SIMV Mode
41
Simv
41
Paediatric Use
42
Anaesthesia Ventilation with the Kuhn System
43
Checking Water Traps
44
At the Water Separator in the Gas Sampling Hose
44
In the Breathing Hoses
44
Monitoring with Reduced Alarm Limits
44
Anaesthetic Vaporiser
45
Checking the Soda Lime
45
Changing Patients
46
Secretion Aspirator (Optional)
46
After Use
48
Set Machine to »Standby
48
Monitor Functions
49
Screen Saver
50
Standby Screen
50
Configuring Monitor Functions in »Standby
51
Changing Default Values
51
Invoking the Configuration Menu
51
Pulse Tone, Alarm Tone, Mode
52
Parameters, Record, Interfaces
53
Alarm Limits, Curves, Basic Configuration
54
Calibration
55
Alarms, Anaesthetic Agent
56
Changing to Measuring Mode from »Standby
57
Monitor Functions During Operation
57
Select Standard Screen, Select Data Screen
57
Select Trend Screen with Zoom Function
58
Other Trend Combinations
59
Return to Full Trend
59
Erase Trend Memory
59
Displaying and Setting Alarm Limits During Operation
60
Softkeys
60
Activate and Deactivate CO 2 Alarms
61
Auto Set/Ventilation Alarm
61
Alarm Information
62
Select List Screen
62
Select Curves
63
Using the Volumeter Function
63
Configuration During Operation
64
Alarm Concept
65
Alarm Priority
65
Displaying All Alarms
66
Suppressing the Alarm Tone
66
CO 2 Alarm On/Off
66
Adjusting to the Ventilation Mode
67
Heart/Lung Mode (HLM)
68
Messages, Cause and Remedy
71
Troubleshooting (Messages - Cause - Remedy)
71
Where Messages Occur
72
Location of Valves and Subsystems
73
Messages on the Monitor
74
Messages on the Ventilator
78
Care
79
Stripping down Machine
80
Dismantling Parts
81
Disinfection - Cleaning - Sterilization
83
Care Intervals
84
Care Methods
84
Care Schematic
84
Disinfectant Cleaning in Machines
85
Disinfection with Formaldehyde Vapour
85
Disposing of Consumable Articles
85
Wipe Cleaning
85
Steam Sterilization (121 °C / 134 °C)
86
Sterilization with Ethylene Oxide
86
Tabular Summary
87
Disposal of Apparatus
88
Disposal of Used Batteries and O 2 Sensors
88
Reassembling System
89
Choice of Sensor
95
Safety and Precautions
95
Spo 2 Measurement (Optional)
95
C-Lock-ECG Synchronization (Optional)
96
Tips to Avoid Artefacts
97
Applying Sensors
98
Durasensor DS-100 a
98
Oxisensor D-25 and D-20
98
Oxisensor I-20
99
Oxisensor R-15
100
Check Operational Readiness
101
O 2 Shortage Signal
102
Spo 2 Measurement (Optional)
102
Supply of Anaesthetic Agent
102
Temperature Measurement (Optional)
102
Calibrate Flow Sensor
103
Calibrate Inspiratory O 2 Sensor with 100% O 2
103
Self-Test
103
Calibrate O Sensor for Sidestream Measurement with 100% O
104
Linearity
104
Power Failure Alarm
104
Automatic Ventilation Function
105
Manual Ventilation Function
105
Maintenance Intervals
106
What's What
107
Overall View of the Machine
108
Operating Elements and Displays on Ventilator
109
Operating Elements and Displays on Monitor
110
Operating Elements and Displays on the Gas and Anaesthetic Agent Measuring Tube Bank
111
Elements on Breathing System
112
Connections on the Rear of the Monitor
113
Dimensions / Weight
114
Technical Data
115
Ambient Conditions
116
General
116
Power Supply
116
Breathing System
117
Medical Gas Supply
117
Ventilator
117
Gas Delivery
118
Monitor
118
Pressure Measurement
118
Flow Measurement
118
O 2 Measurement in Main Stream (Inspiration Line)
118
O 2 , CO 2 and Anaesthetic Agent Measurement in Sidestream (Sampling)
119
Spo2 Measurement
120
Data Communication
120
C-Lock™ ECG Synchronization
121
Operating Parameters
121
Descriptions
123
Flow Chart of Self-Test
124
Rebreathing to Match Fresh Gas Flow
126
Ventilation with Automatic Adjustment of
126
Automatic Compliance Correction
127
Automatic Leakage Tests IPPV / man
127
Notes on Setting Fresh Gas Flow
128
Relationship between Fresh Gas and Gas Concentration in Breathing System
128
Relationship between Fresh Gas and Time Constants in Breathing System
128
Principles of Measurement
129
O 2 Measurement
129
Flow Measurement
129
CO 2 and Anaesthetic Agent Measurement
129
Spo 2 Measurement
131
Temperature Measurement
132
Pressure Measurement
132
Definition of Low-Flow and Minimal-Flow Anaesthesia
132
SIMV, Synchronised Intermittent Mandatory Ventilation
133
S-ORC, O 2 Ratio Control
135
Notes for Reducing Condensation
136
Safety Features of Gas Supply
136
Operation of the Ceiling Version
137
Cato with Ceiling Suspension Unit DVE 808X
137
General Requirements
137
Connecting the Cato Ceiling Version
138
Disconnecting the Cato Ceiling Version
139
Additional Maintenance and Care Instructions
140
What to Do if Problems Arise
140
Abbreviations Used
141
Symbols Used
142
Index
143
Advertisement
Advertisement
Related Products
Dräger caleo
Dräger Infinity C700
Dräger Infinity C500
Dräger CVP 5220
Dräger CF 800
Dräger Cabin Breathing System 1000
Dräger CBS 1000
Dräger Isolette C2000
Dräger Carina
Dräger Cato PowerPack
Dräger Categories
Medical Equipment
Respiratory Product
Measuring Instruments
Test Equipment
Gas Detectors
More Dräger Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL