ENTER/EXIT PROGRAMMING MODE

Object Sense Control

This feature controls the illumination idle. It determines whether the main illumination is
controlled by the Object Sensing system, or alternatively, stays continuously on.
Enable
Disable
To set this feature:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan your selection from the barcodes below. You'll need to cover any unused bar‐
codes on this and the facing page to ensure that the scanner reads only the barcode
you intend to scan.
3. Complete the programming sequence by scanning the Enter/Exit Programming Mode
barcode.
DEFAULT
02FD00(CR)
Object Sense Control =Disable
52
MAGELLAN™ 1500I
= Illumination is controlled by using Object Sense
= Normal illumination is used but it goes off during sleep mode / disable mode
02FD01(CR)04EA40(CR)04CD09(CR)
Object Sense Control = Enable